Installer's Guide
Before removing the door from the unit, remove the power
cable plug from the socket located in the corner of the door.
Rotate Latches
Power cable connection
Figure 30 Rotating Door Latches
Figure 31 Pre-Filter
Figure 32 Collection Cells
VACUUM CLEANING
Vacuuming is the preferred method to clean the PRE-
FILTER and COLLECTION CELLS. It is recommended
that the PRE-FILTER and the COLLECTION CELLS be
vacuumed outside the home to ensure particles on the
filters are not reintroduced into the air. Persons highly
sensitive to the collected particles should wear
appropriate respiratory protection while cleaning.
PRE-FILTER –
It is time to clean the PRE-FILTER when the red "PRE-
FILTER" light (shown in Figure 29) is illuminated.
20
Numbers in [brackets] are for 50 Hz international systems.
The air cleaner is factory set to notify the home owner to
clean the PRE-FILTER every two months [10 weeks] of
actual run time of the air cleaner. This notification can
be changed by the installer/home owner to 1 month [5
weeks] or 3 months [15 weeks] depending on the
conditions in the home (pets, smokers, etc.). Please
see "SET-UP MODE" (Page 13) to change the factory
settings.
1. Using a vacuum hose, vacuum in even strokes
across the length of the PRE-FILTER. After
vacuuming the entire PRE-FILTER using even
strokes going in one direction, repeat the
process using even strokes going in the
opposite direction as shown in Figure 33.
Figure 33 Vacuuming the Pre-filter
NOTE: Do NOT replace the plastic PRE-FILTER with
a metal type PRE-FILTER. A metal PRE-FILTER will
cause reduction in efficiency and potential failure of
the electronics in the air cleaner.
COLLECTION CELLS
The clean/dirty LED light bar indicator will illuminate as
the system cleans the air. The LED lights will progress
from green to yellow and then to red. When the last red
indicator is flashing, it is time to clean the COLLECTION
CELLS (see Figure 31). The air cleaner is factory set to
notify the home owner to clean the COLLECTION
CELLS every six months [31 weeks] of actual run time
of the air cleaner. This notification can be changed by
the installer/home owner to 2 months, 4 months, 6
months, or 9 months [10, 20, 31, or 46 weeks]
depending on the conditions in the home (pets, smokers,
etc.). Please see "SET-UP MODE" (Page 13) to change
the factory settings.