Surround Installation, Contemporary Cast - Napoleon EPI3 Installation And Operating Instructions Manual

Napoleon epi3 wood insert installation and operating instructions
Table of Contents

Advertisement

5.4

SURROUND INSTALLATION, CONTEMPORARY CAST

A.
Line up the 3 holes on the right retaining bracket with the corresponding holes on the right side of the
appliance. Screw into place as shown using 1/4-20 hex head screws. Repeat this procedure on the left
side of the appliance.
B.
Using 1/4-20 round-head screws, thread the screw approximately 1/2 of it's length into the keyed
bracket (2 per side).
C.
Place the casting pieces face down on a protected surface and assemble as shown. Fasten the
securing brackets.
D.
Screw the corner brackets into place as shown on both sides of the casting.
E.
Lift the casting and place the keyed holes onto the 1/4-20 round head screws and rest the casting into
place. Adjust screws as necessary to stabilize the casting.
D
B
1/4-20 ROUND
HEAD SCREWS
A
RETAINING
BRACKET
SECURING
BRACKET
CORNER
BRACKET
KEYED BRACKET
(LEFT & RIGHT)