About The Boiler - Potterton Powermax HE 85 Litre Installation And Servicing Instructions

Condensing boilers with integrated hot water storage
Table of Contents

Advertisement

About Safety
Benchmark Installation, Commissioning and Service
Record Log Book
Potterton is a member of the Benchmark initiative and fully
supports the aims of the programme. Benchmark has
been introduced to improve the standards of installation
and commissioning of central heating systems in the UK
and to encourage the regular servicing of all central
heating systems to ensure safety and efficiency.
Important – Failure to install and commission this
appliance to manufacturer's instructions may invalidate
the warranty. This note does not affect your statutory
rights.
CORGI
All CORGI registered installers carry a CORGI
identification card and have a registration number. Both
should be recorded in your boiler Log Book.
You can check your installer is registered by telephoning
+44 (0) 1256 372300 or writing to:-
CORGI. 1 Elmwood, Chineham Business Park, Crockford
Lane, Basingstoke, RG24 8WG.
Important - Installation, Commissioning, Service &
Repair
This appliance must be installed in accordance with the
manufacturer's instructions and the regulations in force.
Read the instructions fully before installing or using the
appliance.
In GB this must be carried out by a competent person as
stated in the Gas Safety (Installation & Use) Regulations.
Definition of competence: A person who works for a
CORGI registered company and holds current certificates
in the relevant ACS modules, or valid ACoP equivalents, is
deemed competent.
In IE this must be carried out by a competent person as
stated in I.S. 813. "Domestic Gas Installations".
This appliance must be earthed. Connection shall be
made to a 230 V ~ 50 Hz supply. The appliance must
be protected by a 3 amp fuse.
Do not interfere with any sealed components on this
appliance
The appliance must not be operated without the casing
correctly fitted. It is important that the inner casing
panels are not removed for any reason other than for
servicing by a qualified service engineer.
Regular skilled servicing is required to maintain the safe
and efficient operation of your boiler throughout its
working life. Further information on this subject is given
at a later stage.
2
User's Instructions
If it is known or suspected that a fault exists on the a
ppliance, it must not be used until the fault has been
corrected by a competent person. If a gas leak is
suspected turn off the appliance and consult your local
gas supplier or service engineer.
TM
Flammable materials must not be stored in close
proximity to the boiler.
Do not obstruct any purpose provided ventilation
openings.
The minimum clearances must be observed at all times
for safety and servicing.
Front - 450 mm (unless behind openable door).
Top - 200 mm twin pipe vertical flue/250 mm concentric
flue though 400 mm is recommended for both instances.
Do not hang items on the boiler to dry. If a storage
shelf is fitted it should be at least 75 mm above the top
of the case and removable.
Any warning labels on the appliance must be adhered
to.
The programmer has a replaceable battery (to provide
memory for the programmer set and default times). The
battery must be disposed of in a safe manner.
About the Guarantee
Information about your guarantee is detailed separately.
Please note that it only covers the boiler and not your
pipework, radiators, valves, etc. If you call a Potterton
service engineer out during the guarantee period to
anything other than an actual boiler fault- you will be
charged for the visit and any work carried out.

About the Boiler

This is a Floor Mounted, Fan Assisted Balanced Flue
Gas Boiler. This boiler is for use with Natural Gas (G20)
only at 20 mbar and for use in GB/IE only.
The information given in these instructions will help you
obtain the maximum comfort from your boiler with the
minimum trouble and cost. Please take time to read
through these instructions as they will help you
understand how to get the best use out of the boiler.
Powermax HE is a condensing combination boiler in
which the gas burner heats the contents of the built-in
hot water store to provide domestic hot water. A pre-
mixed burner is used to ensure that the gas is burned
cleanly and efficiently.
To reduce running costs, timed operation of the central
heating is essential and a Powermax programmer is
built-in to provide this function. It enables both hot water
and heating periods to be timed for both comfort and
economy. Your installer may have fitted another make
of programmer remote from the boiler and should have
provided you with instructions on its use.
Publication No. 5106228