Prem-I-Air Isla Gurney Installation And Operating Instructions Manual

Advertisement

Quick Links

Installation and Operating
Please hand these instructions to the stove user when the
installation is complete. Leave the system ready for operation
and instruct the user in the correct use of the appliance and
operation of controls.
Installation – Must be installed by a qualified plumber or
suitably qualified fitter
ISLA RANGE OF
FREESTANDING
WOODBURNING
S T O V E S
Instructions
Revision 0

Advertisement

Table of Contents
loading

Summary of Contents for Prem-I-Air Isla Gurney

  • Page 1 ISLA RANGE OF FREESTANDING WOODBURNING S T O V E S Installation and Operating Instructions Please hand these instructions to the stove user when the installation is complete. Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls.
  • Page 2: Assembly Instructions

    Assembly Instructions PLEASE READ THESE INSTRUCTIONS CAREFULLY It is important that your stove is correctly installed, as Prem-i-air cannot accept responsibility for any fault arising through incorrect installation. Carefully remove the steel straps Your Prem-i-air stove comes and lift off the upper crate...
  • Page 3 1. Remove stove from pallet and carefully tip it over onto its back. 2. Sort out the legs and fixings. 3. Ensure the tapped holes, on the base, are free from obstruction. Use a sharp screwdriver to remove any fire cement. Secure the legs and fixings using the screws and washers provided Revision 0...
  • Page 4 1. Fit the Flue Collar using the 4-M6 set screws and washers supplied. If the Top Flue position is required remove the fitted Flue Cover and refit on the rear opening. 2. To fit the Baffle: Insert the baffle, upside down, as shown, ensuring you are holding the shorter of the two sides.
  • Page 5: List Of Components

    List of Components Description of Parts Door Handle Airwash Control Handle Primary Air Caps Riddling Handle Ash Pan Ash Pan Tool Coal Guard Baffle Plate Legs Leg Height Screws M17 Leg Screws M14 Leg Washers Flue Collar Flue Collar Screws M10 Flue Collar Nuts M10 Flue Collar Washers Revision 0...
  • Page 6 Revision 0...
  • Page 7: Installation Instructions

    Installation Instructions READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION These instructions cover the basic principles to ensure satisfactory installation of the stove, although detail may need slight modification to suit particular local site conditions. In all cases the installation must comply with National and European Building Regulations, Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove.
  • Page 8: Installation

    There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room. Installation Chimney The chimney height and the position of the chimney terminal should conform to Building Regulations.
  • Page 9 Material Clearances The stove can be recessed in a suitable sized fireplace but a permanent free air gap of at least 150mm must be left around the sides and top and at least 50mm at the back of the stove to obtain maximum heat output and for access to the rear of the stove. All non-combustible walls closer than 400mm to the stove should be at least 75mm thick.
  • Page 10: Operating Instructions

    Operating Instructions This appliance is not suitable for use in a shared flue. This appliance should not be operated with the doors open. Aerosol Sprays Do not use an aerosol spray on or near the stove when it is alight. Air Controls This stove has been designed to burn clean and efficient.
  • Page 11 Multifuel Grate Your Prem-i-air Stove is fitted with a rotary style grate, which is operated from the front of the stove via a riddle rod. Use the “Hook” end of tool to operate the riddling system.
  • Page 12 Size of Fuel Log Size Gurney up to 260mm Stockay up to 300mm Calvay up to 340mm Lighting the Stove We recommend that you have two or three small fires before you operate your stove to its maximum heat output. This is to allow the paint to cure in steadily and to give a long service life of the paint finish.
  • Page 13: Safety Notes For Your Guidance

    Safety Notes for your guidance FIRES CAN BE DANGEROUS – Always use a fireguard in the presence of children, the elderly or the infirm. DO NOT OVERFIRE – it is possible to fire the stove beyond its design capacity, this could damage the stove, so watch for signs of overfiring –...
  • Page 14: Frequently Asked Questions

    A call out charge will apply if our engineer attends any stove problem that is not related to product failure. 6 Where can I get spare parts? Prem-i-air will be pleased to supply spare parts and to provide any other information you require. Revision 0...
  • Page 15 7 Can the doors be left open while burning? For safety and heat efficiency the doors should remain closed at all times. 8 Why is the stove smoking when lit? A smoking stove can be caused by a flue with back draught problems. A qualified fitter should complete a smoke test prior to fitting the stove to ascertain the integrity of the flue.
  • Page 16 Email : sales@prem-i-air.co.uk Sales Telephone : 01744 745030 Fax : 01744 745001 Email : helpdesk@prem-i-air.co.uk Product Support Telephone : 01744 745030 Fax : 01744 745001 Email : spares@prem-i-air.co.uk Spare Parts Telephone : 01744 745030 Fax : 01744 745001 Revision 0...