10.ELECTRIC CIRCUIT FIX

PROBLEM
1:room temperature sensor damage
SHOW E1
SHOW E2
1:eva temperature sensor damage
1:without power supply
2:without power into transformer
WITHOUT ACTION
3:without power out from transformer transformer damage,replace it
4:without power out from 7805
CAUSE
HOW TO FIX IT
replace the sensor or call service center
replace the sensor or call service center
check power and plug connect on or not
check power fuse connect or not
replace 7805 (mark on IC3)