Download Print this page

Tank Full Indicator; Drainage Instructions; Water Tank; Continuous Drainage - Dimplex GDDEU30 User Manual

Advertisement

The fan will continue to run until the unit is switched off.
Comfort Mode (Indicated by: AU)
a. When ambient temperature is below 5
b. When ambient temperature is between 5
set the humidity level at 60%
c. When ambient temperature is between 20
automatically set the humidity level at 55%
d. When ambient temperature is above 27
humidity level at 50%
Continuous Mode (Indicated by: CO)
The continuous mode allows the dehumidifier to run continuously at a set
humidity level. The unit will only stop once the water tank is full.

TANK FULL INDICATOR

If this indicator illuminates, it shows that the water tank is full. The
compressor and fan will stop automatically until the water tank is emptied.
PRECAUTIONS
1. The dehumidifier will not operate if the humidity setting is higher than the
ambient humidity.
2. Drain the water in the water storage tank when the water tank is full and
the water level indicator light illuminates. Reinstall the empty water tank
back to its position, so the unit can continue its operation.
3. When the unit stops, it is required that you wait for 3 minutes before you
restart the unit to protect the compressor from damage.
4. The operating temperature range for this unit is 5-32
5. If the dehumidifier does not start (i.e. the operation light does not
illuminate) or the dehumidifier makes intermittent stops for unknown
, the compressor will switch off.
and 20
, it will automatically
and 27
, it will
, it will automatically set the
o
C
4
reasons, please check the plug and power supply for a poor power
connection. If the plug and power supply is in normal condition, wait for
10 minutes and restart the unit (it takes about 10 minutes to reset). If the
unit still does not start in 10 minutes, please contact your local retailer/
service agent for repair.
6. When the dehumidifier is in operation, the running compressor can
sometimes produce heat and make the room temperature higher. This is
normal.
7
I f the defrost light illuminates – it indicates that the unit is in defrost mode.
During this operation mode the compressor is switched off, however the
fan motor will still be running. The unit should resume normal operation
after several minutes.

DRAINAGE INSTRUCTIONS

The extracted water can be collected in the water tank, or drained
continuously with a PVC hose (not supplied):

WATER TANK:

When the Tank Full indicator illuminates, the tank is
full, the compressor and the fan will stop operation,
please empty the water tank:
1. Remove the water tank as Fig 01. and empty it.
2. Insert the water tank gently back into the unit to
its original position.

CONTINUOUS DRAINAGE

When you want to use this function please pull out
the water tank and plug a PVC water discharge pipe
5
Fig 01
Fig 02

Advertisement

loading