High Voltage Cable - Dometic S1521 Service Tips Manual

Table of Contents

Advertisement

IGNITER
Verify proper voltage at the positive (+) and ground (–)
terminals of the igniter. Remove high voltage cable fro
igniter. The igniter should produce a sparking sound during
trial-for-ignition. The igniter installed on the refrigerators as
original equipment is part number 2931132019 (RV Gas
Model 679). This igniter is rated 50 MA. This igniter may
also be used on any other model.
DO NOT install the Channel Mark 6, Model 12E Igniter
(shown below) as a service replacement part.
MARK 6, MODEL 12E
CHANNEL P RODUCTS INC.
R
CHESTERLAND, OHIO 44026
Installation of the Channel Products, Inc., Gasliter Mark 6, Model 12E will VOID the Warranty on the
refrigerator.

HIGH VOLTAGE CABLE

Disconnect high voltage cable from electrode. If sparking starts during trial-for ignition, the cable is
good.
ELECTRODE
Do a visual check for cracks or breaks on the ceramic insulator. If either of the above is found, replace
the electrode. The spark gap must be set at three sixteenths (3/16") of an inch and tip of electrode
above the slots in the burner.
16
+
L
12VDC 25 MA
ELECTRODE
TIP
BURNER
GASLITER
MARK 6, MODEL 12E
W/O 1282150 9318
3/16"
+ L G
12VDC
25mA
CHANNEL P RODUCTS
CHESTERLAND OH 44026

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents