NPM-5
RF Troubleshooting
7URXEOHVKRRWLQJ FKDUW IRU 3// 6\QWKHVL]HU
From WinTesla chose:
Product > Band > EGSM
Testing > RF Controls >
Rx continuous > Ch 60
Spectrum Analyzer
No
VCO output ( G500 out)
3788 MHz
Yes
PLL block functional
,W LV LPSRUWDQW WR VD\ WKDW SRZHU VXSSO\ IRU 9&7&;2 9;2 LV 2)) RQO\ LQ ¨'HHS 6OHHS
0RGH© DQG SRZHU VXSSO\ IRU 9&2 * 9FF LV 2)) LQ ¨6OHHS 0RGH©
3DJH
)LJXUH 3// V\QWKHVL]HU WURXEOHVKRRWLQJ
Oscilloscope
Yes
VCTCXO Power Supply
(G502 Vcc)
2,7 V
No
Check CCONT,
Software?? Phone not in
function
Check HAGAR,
wrong writting to HAGAR
(SCLK,SDATA,SLE,
HAGARRESET)
1RNLD &RUSRUDWLRQ
PAMS Technical Documentation
Oscilloscope
Yes
VCTCXO output
(G502 out) 26 MHz,
approx. 1.2 Vpp
No
VCTCXO is dead
Yes
Oscilloscope
Yes
VCO Power Supply
(G500 Vcc) 2,7 V
No
Check CCONT,
Software?? Phone not
in function
Spectrum Analyzer
VCO output ( G500 out)
Some signal between 3
and 4 GHz
No
VCO is dead
,VVXH