Download Print this page

Mounting The Detector; Wiring The Terminal Blocks - Bosch ISC-PPR1-W16G Installation Instructions Manual

Pir detector professional series

Advertisement

2.3

Mounting the detector

Use the hardware provided. The plastic mounting anchors
require a 3/16 (5 mm) hole.
Surface mounting
1 Tamper Screw
Corner Mounting
2.4
Wiring the detector
Wire sizes between 16 AWG and 26 AWG (0.2 mm
mm
) are permitted. Install the wiring using the approprate
2
knock-outs and tie-downs.
© 2009 Bosch Security Systems, Inc.
2.5

Wiring the terminal blocks

The detector has two terminal blocks. One block is used for
primary wiring; the other has two spare terminals. The two
spare terminals are normally used as tie points for the EOL
resistor.
and 1
2
Do not attempt to remove the terminal blocks from
the cover. This could result in permanent damage
to the detector.
3

Advertisement

loading