Technical Cautions - Hitachi 53SWX10B Service Manual

Projection color television
Hide thumbs Also See for 53SWX10B:
Table of Contents

Advertisement

High Voltage limiter circuit operation check.
1. Turn off TV and connect jig as shown in Figure 2. Adjust
jig fully counter-clockwise for minimum resistance.
2. Set the AC input to 120V AC and turn on TV.
3. Confirm test pattern on CRT is a usable picture, then
slowly adjust jig until the picture disappears and TV shuts
down.
AC CORD POLARITY
This check is based on the UL standard. Use the jigs specified by the production technology section. The GND side (wider
blade) of the AC power cord should be connected to K9Y1

TECHNICAL CAUTIONS

L902
L901
C901
TESTER
4. When the limiter circuit is operating properly, High
Voltage will be less than 31.5 kV at 1.7mA when TV shuts
down.
5. Turn off set immediately after checking circuit operation.
6. Unplug set for one minute to reset shutdown circuit.
Remove jig and voltmeter.
(TH01)
EF901
EF901
F901
2
PA
1
KKA1
WHITE side
GND side
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

53uwx10b61swx10b53swx12b61uwx10b61swx12b43uwx10b

Table of Contents