Goodman GMH95 Technical Manual page 16

40" 95%
Hide thumbs Also See for GMH95:
Table of Contents

Advertisement

WIRING DIAGRAMS
HUMIDIFIER
24V THERMOSTAT
CONNECTIONS
C
G
R
FUSE
INTEGRATED
CONTROL
MODULE
ON
*
FACTORY SETTINGS
SHOWN
DIAGNOSTIC
LED
115 VAC HOT AND PARK TERMINALS
COOL-H
GND
WH
BR
BR
CAPACITOR
BLOWER COMPARTMENT
BURNER COMPARTMENT
GND
BK
WH
RD
OR
N
O
WH
ID BLOWER
PRESSURE
SWITCH
2 CIRCUIT
CONNECTOR
HOT
SURFACE
IGNITER
STEADY ON = NORMAL OPERATION
0
OFF
= CONTROL FAILURE
1 FLASH
=
1
2 FLASHES = PRESSURE SWITCH STUCK CLOSED
2
3 FLASHES = PRESSURE SWITCH STUCK OPEN
3
4
4 FLASHES = OPEN HIGH LIMIT
5 FLASHES = FLAME SENSE WITHOUT GAS VALVE
5
6 FLASHES =
6
7 FLASHES = LOW FLAME SIGNAL
7
8
8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING
CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY
C
COLOR CODES:
YL YELLOW
OR ORANGE
PU PURPLE
GN GREEN
BK BLACK
0140F00647 REV. B
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
16
OR
24 VAC
GY
24 VAC
40 VA
TRANSFORMER
115 VAC
W
Y
WH
BK
OR
3
2
1
PU
OR
6
5
4
9
8
BL
7
GR
OFF
YL
12
11
10
2ND
STAGE
OR
*
DELAY
OR
GY
*
BR
MODE
RD
HEAT
GY
OFF
OR
*
DELAY
WH
FS
SEE
NOTE 6
2
WH
1
HEAT-H
BK
LINE-H
SEE
NOTE 4
GY
BK (HI)
PK
RD
BL (MED)
OR (MED LOW)
RD (LOW)
BK
CIRCULATOR
BLOWER
YL
GY
PU
WH
INDUCED DRAFT
BLOWER
WH
AUTO RESET
PRIMARY LIMIT
PU
CONTROL
BL
YL
OR
C
PK
MANUAL RESET ROLLOUT LIMIT CONTROL(S)
( SINGLE CONTROL ON 45K BTU )
24 VAC
HUMIDIFIER
FRONT COVER
PRESSURE SWITCH
N
C
PM
GY
O
1
GND
C
OR
2
BR
HI
3
GAS VALVE
(HONEYWELL)
SYSTEM LOCKOUT (RETRIES EXCEEDED)
OPEN ROLLOUT OR OPEN FUSE
NOTES:
PK PINK
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
BR BROWN
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
WH WHITE
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL
HAVING A TEMPERATURE RATING OF AT LEAST 105
BL BLUE
4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED
GY GRAY
BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.
RD RED
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN
STANDBY (NO THERMOSTAT INPUTS)
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
C
G
TO
Y
MICRO
GY
W
R
TH (3)
XFMR-H
IGN
IND
EAC-H
LINE-H
DOOR
SWITCH
WARNING:
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
AND GROUNDED.
TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH
OVERCURRENT PROTECTION DEVICE
RD
JUNCTION
BL
BOX
GY
WH
GR
BK
FLAME
SENSOR
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (115V)
HI VOLTAGE FIELD
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION
°C. USE COPPER CONDUCTORS ONLY.
GMH950905CXAA
HUMIDIFIER
INTEGRATED
CONTROL MODULE
TR (6)
C
GND
GND (8)
GAS
HI
VALVE
MVC (9)
PM
MVH (12)
AUXILIARY LIMIT CONTROLS
C
MVL(2)
NO
FRONT COVER
PS (10)
PRESSURE SWITCH
PSO (4)
HLI (7)
HLO (1)
NO
C
AUTO RESET PRIMARY
LIMIT CONTROL
ID BLOWER
RO2 (11)
PRESSURE
SWITCH
RO1 (5)
MANUAL RESET ROLLOUT
LIMIT CONTROL(S)
(SINGLE CONTROL ON 45K BTU)
24 VAC
40 VA
TRANSFORMER
115 VAC
FLAME SENSOR
FS
HOT SURFACE
IGNITER
ID
BLWR
COOL-H
CIRCULATOR
BLWR
ELECTRONIC
AIR CLEANER
JUNCTION BOX
DISCONNECT
GND
L
N
WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
N
GND
L
DISCONNECT
EQUIPMENT GND
FIELD GND
FIELD SPLICE
SWITCH (TEMP.)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents