1. SAFETY PRECAUTIONS

Read this manual thoroughly, paying special
attention to the sections that apply to you, before
working with the UPS. Retain this manual for
use by installing personnel.
Under typical operation and with all UPS doors
closed, only normal safety precautions are
necessary. The area around the UPS system should
be kept free from puddles of water, excess
moisture, or debris.
Special safety precautions are required for
procedures involving handling, installation, and
maintenance of the UPS system or the battery.
Observe all safety precautions in this manual
before handling or installing the UPS system.
Observe all precautions in the Operation and
Maintenance Manual, before and during
performance of all maintenance procedures.
Observe all battery safety precautions before
working on or near the battery.
This equipment contains several circuits that
are energized with high voltage. Only test
equipment designated for troubleshooting should
be used. This is particularly true for oscilloscopes.
Always check with an AC and DC voltmeter to
ensure safety before making contact or using tools.
Even when the power is turned Off, dangerously
high potentials may exist at the capacitor banks
and at the batteries.
ONLY qualified service personnel should
perform maintenance on the UPS system.
When performing maintenance with any part of
the equipment under power, service personnel and
test equipment should be standing on rubber mats.
The service personnel should wear insulating
shoes for isolation from direct contact with the
floor (earth ground).
Unless all power is removed from the equipment,
one person should never work alone. A second
person should be standing by to assist and
summon help in case an accident should occur.
Four types of messages are used throughout the
manual to stress important text. Carefully read the
text below each Danger, Warning, Caution, and
Note and use professional skills and prudent care
Liebert Series 600T UPS, 65-225 kVA, Single Module
INSTALLATION
when performing the actions described by that
text.
A Danger signals immediate hazards resulting in
severe personal injury or death. For example:
DANGER
A DANGER SIGNALS IMMEDIATE
HAZARDS WHICH WILL RESULT IN
SEVERE PERSONAL INJURY OR DEATH.
A Warning signals the presence of a possible
serious, life-threatening condition. For example:
WARNING
LETHAL VOLTAGES MAY BE PRESENT
WITHIN THIS UNIT EVEN WHEN IT IS
APPARENTLY NOT OPERATING.
OBSERVE ALL CAUTIONS AND
WARNINGS IN THIS MANUAL. FAILURE
TO DO SO COULD RESULT IN SERIOUS
INJURY OR DEATH. DO NOT WORK ON OR
OPERATE THIS EQUIPMENT UNLESS
YOU ARE FULLY QUALIFIED TO DO SO!!
NEVER WORK ALONE.
A Caution indicates a condition that could
seriously damage equipment and possibly injure
personnel. For example:
CAUTION
Extreme care is necessary when removing
shoring braces. Do not strike the cabinet
with hammers or other tools.
A Note emphasizes important text. If the note is
not followed, equipment could be damaged or may
not operate properly. For example:
NOTE
If the UPS system has a blown fuse, the
cause should be determined before you
replace the fuse. Contact Liebert Global
Services.
1