Liebert 700-2200 VA User Manual

700-2200 va 120 v

Advertisement

P
P
OWER
ROTECTION
R
PowerSure™ Interactive
700-2200 VA
120 V
U
M
SER
ANUAL
English

Advertisement

Table of Contents
loading

Summary of Contents for Liebert 700-2200 VA

  • Page 1 OWER ROTECTION PowerSure™ Interactive 700-2200 VA 120 V ANUAL English...
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product yourself except to replace the battery. Opening or removing the cover may expose you to dangerous voltages, even when the AC cord is disconnected from the electrical outlet. Refer all servicing to qualified service personnel. 1.
  • Page 3 If unable to fully insert the plug into the wall outlet, contact a qualified electrician for assistance. 10. Route power supply cords so they are not walked on or pinched. 11. Never block or insert any object into the ventilation holes or other openings.
  • Page 4: Introduction & System Description

    INTRODUCTION & SYSTEM DESCRIPTION Congratulations on your choice of the Liebert PowerSure™ Interactive Uninterruptible Power System (UPS). It provides conditioned power to microcomputers and other sensitive electronic equipment. Upon generation, AC power is clean and stable. However, during transmission it may be subject to voltage sags, spikes, or complete power failure which may interrupt computer operations, cause data loss, or even damage equipment.
  • Page 5: Major Components

    TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) AND EMI/RFI FILTERS These UPS components provide surge protection and filter Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI). They minimize any surges or interference present in the utility line and keep the sensitive equipment protected.
  • Page 6 MINI-TOWER INSTALLATION Unpack the UPS carefully noting the packing method. Retain the box and packing material for possible future shipment. CAUTION: The UPS is heavy (see specifications). Take proper precautions when lifting or moving it. Visually inspect the UPS for freight damage. Report damage to the carrier and your dealer.
  • Page 7: Rack Mount Installation

    RACKMOUNT INSTALLATION Unpack the UPS carefully noting the packing method. Retain box and packing material for possible future shipment. CAUTION: The UPS is heavy (see specifications). precautions when lifting or moving the UPS. Visually inspect the UPS for freight damage. Report any damage to the carrier and your dealer.
  • Page 8: Controls And Indicators

    24 hours. After 24 hours, retest the batteries. If the batteries have been retested and the top two LEDs still do not illuminate, contact your dealer or Liebert Technical Support (LTS) for a battery replacement kit. Site Wiring Fault Indicator (RED) An illuminated LED indicates the UPS has detected a miswired utility receptacle.
  • Page 9 POWERSURE™ INTERACTIVE MINI-TOWER Fault Indicator Load/Battery Level Indicators Alarm Silence/ Battery Test Button On/Off Button Output Receptacles DB-9 Interface Port AC Inlet Intellislot™ Communications Port Circuit Protector or Fuse Site Wiring Fault Indicator 700 VA 1000 / 1400 VA Utility High/Low Indicator Utility/Battery Status Indicator...
  • Page 10 POWERSURE™ INTERACTIVE RACKMOUNT Fault Indicator Load / Battery Level Indicators Load / Battery Utility High / Low Alarm Silence Alarm Silence / Battery Test Button *700 Model has detachable cord Output Receptacles DB-9 Interface Port AC Inlet Intellislot™ Communications Port Circuit Protector or Fuse Site Wiring Fault Indicator Utility High / Low Indicator...
  • Page 11: Operation

    NORMAL MODE OPERATION During normal operation, utility power provides energy to the UPS. The filters and the power conditioning circuit process this power to provide computer grade power to connected loads. The UPS maintains the batteries in a fully charged state. The front panel displays the percentage of load on the UPS output.
  • Page 12 BATTERY MODE OPERATION Battery mode occurs in event of extreme input conditions or complete utility failure. The battery system along with the bi-directional converter generates power for the connected load. During battery mode an alarm sounds every 10 seconds. This will change to 2 beeps every 5 seconds when battery runs low (approximately 2 minutes remaining).
  • Page 13: Communications Interface Port

    Monitoring of the UPS via a computer system is easily made with a Liebert SiteNet® 1 shutdown kit (sold separately).
  • Page 14: Ups Intelligent Communications

    Timed and delayed shutdown of the UPS Logging of power disturbances and anomalies • Contact your local Liebert representative, dealer, or reseller for more information about SiteNet® 2 software. UPS INTELLISLOT™ COMMUNICATIONS The PowerSure™ Interactive UPS contains an Intellislot™ communications port for the optional internal communications, such as the Ethernet SNMP card.
  • Page 15 • If you feel unqualified to replace the battery, do not open the battery door. Call Liebert Technical Support (LTS). World Wide Technical Support numbers are located at the end of this section. Grasp the front bezel near the top and pull forward.
  • Page 16 MINI-TOWER BATTERY REPLACEMENT Pull bezel forward Rotate bezel on top Remove battery door 700 VA Model To Disconnect: Gently pull wiring away To Connect: Connect red wire to red terminal, then black wire to black terminal by pushing towards connector 1000/1400 VA Model To Disconnect: Gently pull wiring away...
  • Page 17 Do not dispose of batteries in a fire, the batteries may explode. If you feel unqualified to replace the battery, do not open the battery door. Call Liebert Technical Support (LTS). World Wide Technical Support numbers are located at the end of this section.
  • Page 18 Figure 1 Figure 3 Figure 4 Figure 6 Figure 2 Figure 5 Figure 7...
  • Page 19: Troubleshooting

    The fault indicators will be illuminated indefinitely while battery charger is operational, or for a maximum of 5 minutes while battery charger is not operational. If a problem persists consult your dealer, or contact Liebert Technical Support (LTS). World Wide Technical Support numbers are located at the end of this section.
  • Page 20: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM UPS fails to start when On/Off button is pressed Utility indicator flashing UPS has reduced battery time “Fault” indicator and diagnostic LED “A” are illuminated “Fault” indicator and diagnostic LED “B” are illuminated UPS shut down. “Fault” indicator and diagnostic LED “D”...
  • Page 21 POWERSURE™ INTERACTIVE TYPICAL BATTERY DISCHARGE CURVES (Discharge times are at 25° C ambient) 700 VA Percent Load 1400 VA Percent Load 1000 VA 2200 VA Percent Load Percent Load...
  • Page 22 CAUTION: Before changing the supply fuse, turn off the UPS, and unplug the input cord from the AC input power supply and from the UPS. Remove the fuse holder by inserting a flat blade screwdriver into the slot and pulling out as indicated in the figure above.
  • Page 23 MINI-TOWER SPECIFICATIONS Model Number PS700MT-120 Model Rating VA/W DIMENSIONS: in (mm) Unit W x D x H Shipping 10.5 x 19.2 x 11.75 W x D x H WEIGHT: lbs (kg) Unit Shipping INPUT AC PARAMETERS Voltage Range Voltage Raise Voltage Lower Frequency Input...
  • Page 24: Rackmount Specifications

    RACKMOUNT SPECIFICATIONS Model Number Model Rating VA/W DIMENSIONS: in (mm) Unit W x D x H Shipping W x D x H WEIGHT: lbs (kg) Unit Shipping INPUT AC PARAMETERS Voltage Range Voltage Raise Voltage Lower Frequency Input 6 ft. detachable, w/ Power Cord OUTPUT AC PARAMETERS Output Receptacles...
  • Page 26: Technical Support

    Worldwide FAX Tech Support...…614-841-5471 The Company Behind The Products With more than 500,000 installations around the globe, Liebert is the world leader in computer protection systems. Since its founding in 1965, Liebert has developed a complete range of support and protection systems for sensitive electronics: •...