Electrostatic Discharge Requirements; Emc; Reliability - BenQ G2420HD Product Service Manual

Benq g2420hd 24’ lcd monitor
Hide thumbs Also See for G2420HD:
Table of Contents

Advertisement

(2) Unpackaged Vibration
(3) Drop
(4) Shock
3.1.3.6

Electrostatic Discharge Requirements

Item
Electrostatic Discharge
3.1.3.7

EMC

Item
TCO03
EMI
3.1.3.8

Reliability

Item
MTBF Prediction
CCFL Life time
Note-4: CCFL lifetime is determined as the time at which brightness of lamp is 50%. The typical
lifetime of CCFL is on the condition at 7.0mA lamp current.
Unpackaged, Non-
Operating
Package, Non-Operating
Wooden package, Non-
Operating
Condition
IEC801-2 standard
Condition
Electric
Magnetic
FCC part 15J class B
EN55022 class B
Condition
Refer to MIL-217F
At 25±2℃, under 7.0mA
- 13 -
(3) Procedure:
Confirmed sample with
appearance and function
ready
before testing then
compare with after test
record as brightness,
uniformity and contrast
ratio. Perform random
vibration after sine-wave
vibration test.
Test Spectrum:
20 Hz 0.0185(g2/Hz)
200Hz 0.0185(g2/Hz)
Duration : 5 Minutes
Axis : 3 axis
( Horizontal and Vertical
axis ,Z axis)
91 cm Height (MP stage)
(1 corner, 3 edges, 6
faces)
Waveform: half sine
Faces:
6
sides/
orientation
3 shocks.
Duration: <3ms
Velocity accelerate: 75g
Spec
Contact: 8KV
Air: 15KV
Spec
Band 1 < 10 V/m
Band 2 < 1 V/m
Band 1 < 200nT
Band 2 < 25nT
After Mass production
under 1dBuv for constant
measure. Besides DNSF
and VCCI class-2 are
optional.
Spec
> 60,000 Hours
40,000 Hours (min)
per
OK NA Remark
OK NA Remark
OK NA Remark
Excluding
CCFL
See Note-4