Maintenance; Performing Scheduled Maintenance; Maintenance Schedule; Gp5000/Gp6000E/Gp6500E Maintenance Schedule - Generac Portable Products GP Series Owner's Manual

50 hz portable generator
Hide thumbs Also See for GP Series:
Table of Contents

Advertisement

Figure 13 - Battery Charger Jack
BATTERY
CHARGER
INPUT

3.1 PERFORMING SCHEDULED MAINTENANCE

It is important to perform service as specified in the Maintenance
Schedule for proper generator operation, and to ensure that the
generator complies with the applicable emission standards for the
duration of its useful life. Service and repairs may be performed by
any capable person or repair shop. Additionally, emissions critical
maintenance must be performed as scheduled in order for the
Emissions Warranty to be valid. Emissions critical maintenance
consists of servicing the air filter and spark plugs in accordance
with the Maintenance Schedule.

3.2 MAINTENANCE SCHEDULE

3.2.1 GP5000/GP6000E/GP6500E MAINTENANCE
SCHEDULE
Follow the calendar intervals. More frequent service is required
when operating in adverse conditions noted below.
Check Oil Level
Change Oil ‡
Check Valve Clearance
Service Air Filter
Replace Spark Plug
‡ Change oil after first 30 hours of operation then every season.
* Change oil and oil filter every month when operating under heavy load or in high
temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter
parts if they cannot be adequately cleaned.
***
Check valve clearance and adjust if necessary after first 50 hours of
operation and every 100 hours thereafter.
At Each Use
*Every 100 hours or Every Season
***Every Season
** Every 200 hours or Every Season
Every Season

3.2.2 GP2600/GP2800 MAINTENANCE SCHEDULE

Follow the calendar intervals. More frequent service is required
when operating in adverse conditions noted below.
Check Oil Level
Change Oil ¥
Check Valve Clearance
Service Air Filter
Replace Spark Plug
¥
Change oil after first 20 hours of operation.
*
Change oil every month when operating under heavy load or in high
temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter
parts if they cannot be adequately cleaned.
***
Check valve clearance and adjust if necessary after first 50 hours of
operation and every 100 hours thereafter.
**** Clean and re-gap spark plug every 50 hours.

3.3 PRODUCT SPECIFICATIONS

3.3.1 GP5000/GP6000E/GP6500E GENERATOR
SPECIFICATIONS
Rated Power ............................................................5.0/6.0/6.5 kW*/**
Surge Power ...................................................................7.5/9.0/9.0 kW
Rated AC Voltage .............................................................................230
Rated AC Load
Current @ 230V (5.0/6.0/6.5 kW) ..................21.7/26.0/28.2 Amps**
Rated Frequency .................................................... 50 Hz @ 3000 RPM
Phase ................................................................................ Single Phase
Weight (GP5000/GP6000E/GP6500E) .......................82.5 kg (181.5 lbs)/
* Operating temperature range: -18° C (0 °F) to 40 °C (104 °F) When operated
above 25 °C (77 °F), there may be a decrease in engine power.
** Maximum wattage and current are subject to, and limited by, such factors
as fuel Btu content, ambient temperature, altitude, engine condition, etc..
Maximum power decreases about 3.5% for each 1,000 feet above sea level.

3.3.2 GP2600/GP2800 GENERATOR SPECIFICATIONS

Rated. Power ................................................................2.6/ 2.8 kW*/**
Surge Power ...............................................................................3900W
Rated AC Voltage .............................................................................230
Rated Current ...........................................................11.3/ 12.1 Amps**
Rated Frequency .................................................... 50 Hz @ 3000 RPM
Phase ................................................................................ Single Phase
Weight (GP2600/GP2800) .............................................50 kg (110 lbs)
* Operating temperature range: -18 °C (0 °F) to 40 C (104 °F) When operated
above 25 °C (77 °F), there may be a decrease in engine power.
** Maximum wattage is subject to, and limited by, such factors as fuel Btu
content, ambient temperature, altitude, engine condition, etc.. Maximum power
decreases about 3.5% for each 1,000 feet above sea level.

Maintenance

At Each Use
*Every 50 Hours
***Every Season
**Every 25 Hours
****Every 100 Hours
88.9 kg (195.5 lbs)/88.9 kg (195.5 lbs)
13

Advertisement

Table of Contents
loading