LG BX220-JD Owner's Manual page 28

Lg dlp projector owner's manual
Table of Contents

Advertisement

RS-232C
External control device setup
01. Power (Command2:a)
➜ To control Power On/Off of the Projector.
Transmission
[k] [a] [ ] [Set ID] [ ] [Data] [Cr]
Data
0 : Power Off
1 : Power On
Ack
[a] [ ] [Set ID] [ ] [OK] [Data] [x]
Data
0 : Power Off
1 : Power On
➜ To show Power On/Off status.
Transmission
[k] [a] [ ] [Set ID] [ ] [FF] [Cr]
Ack
[a] [ ] [Set ID] [ ] [OK] [Data] [x]
Data
0 : Power Off
1 : Power On
* In like manner, if other functions transmit '0xFF' data based
on this format, Acknowledgement data feed back presents
status about each function.
02. Input Select (Command2:b)
➜ To select input source for the Set.
Transmission
[k] [b] [ ] [Set ID] [ ] [Data] [Cr]
Data
2 : Video
3 : S-Video
6 : RGB-DTV
7 : RGB-PC
9 : DVI-PC
Ack
[b] [ ] [Set ID] [ ] [OK] [Data] [x]
Data
2 : Video
3 : S-Video
7 : RGB-PC
9 : DVI-PC
* The transmission data for RGB-DTV(Data:6) input select is
changed to RGB-PC(Data:7) for the identical mode processing.
In like manner, the data of transmission for DVI-DTV(Data:8)
input select is changed to DVI-PC(Data:9).Therefore,if you send
command to select RGB-DTV or DVI-DTV source,you will recieve
changed data in the Ack message.
28
4 : Component
8 : DVI-DTV
4 : Component
03. Aspect Ratio (Command2:c)
➜ To adjust the screen format.
Transmission
[k] [c] [ ] [Set ID] [ ] [Data] [Cr]
Data 1 : Normal Screen( 4:3)
2 : Wide Screen(16:9)
Ack
[c] [ ] [Set ID] [ ] [OK] [Data] [x]
Data 1 : Normal Screen( 4:3)
2 : Wide Screen(16:9)
04. Screen Mute (Command2:d)
➜ To select screen mute on/off.
Transmission
[k] [d] [ ] [Set ID] [ ] [Data] [Cr]
Data
0 : Screen Mute Off (Picture On)
1 : Screen Mute On (Picture Off)
Ack
[d] [ ] [Set ID] [ ] [OK] [Data] [x]
Data
0 : Screen Mute Off (Picture On)
1 : Screen Mute On (Picture Off)
05. Contrast (Command2:g)
➜ To adjust screen contrast.
Transmission
[k] [g] [ ] [Set ID] [ ] [Data] [Cr]
Data
Min : 0 ~ Max : 64
* Refer to 'Real data mapping 1'.
Ack
[g] [ ] [Set ID] [ ] [OK] [Data] [x]
Data
Min : 0 ~ Max : 64
* Real data mapping 1
0 : Step 0
A : Step 10
F : Step 15
10
: Step 16
64
: Step 100
* Real data mapping 2
0 : Step -50
32 : Step 0
64 : Step 50