Set ID
Set ID
- Use this function to specify a monitor ID number.
- Refer to 'Real Data Mapping 1'. See page 27.
1. Press the MENU button and then use
menu.
2. Press the
G G
button and then use
3. Press the
G G
button and then use
the desired monitor ID number. The adjustment range of
4. Press the ENTER button to save.
Communication Parameters
Communication Parameters
• Baud rate : 9600 bps (UART)
• Data length : 8 bits
• Parity : None
Command Reference List
Command Reference List
COMMAND
01. Power
02. Input Select
03. Aspect Ratio
04. Screen Mute
05. Volume Mute
06. Volume Control
07. Contrast
08. Brightness
09. Color
10. Tint
11. Sharpness
12. OSD Select
13. Key Lock
14. Tune Command
15. Add/Delete
16. Key
17. Auto Configure
26
button to select the
D D / E E
button to select
D D / E E
button to adjust
D D / E E
COMMAND
DATA2
DATA1
(Hexa)
1
2
(Hexa)
k
a
0 ~ 1
k
b
0 ~ 6
k
c
1 ~ 4
k
d
0 ~ 1
k
e
0 ~ 1
k
f
0 ~ 64
k
g
0 ~ 64
k
h
0 ~ 64
k
i
0 ~ 64
k
j
0 ~ 64
k
k
0 ~ 64
k
l
0 ~ 1
k
m
0 ~ 1
m
a
01 ~ 7D
m
b
0~1
m
c
Key Code
j
u
1
.
to choose
is 1 ~ 99.
• Stop bit : 1 bit
• Communication code : ASCII code
T
ransmission / Receiving Protocol
T
ransmission / Receiving Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command 1]: First command. (j or k)
* [Command 2]: Second command.
* [Set ID]: You can adjust the set ID to choose desired monitor
ID number in Special menu. Adjustment range is 1
~ 99. When selecting Set ID '0', every connected
TV set is controlled. Set ID is indicated as decimal
(1~99) on menu and as Hexa decimal (0x0~0x63)
on transmission/receiving protocol.
* [DATA]: To transmit command data.
Transmit 'FF' data to read status of command.
* [Cr]: Carriage Return
ASCII code '0x0D'
* [ ]: ASCII code 'space (0x20)'
OK Acknowledgement
0~1
[Command2][ ][Set ID][ ][OK][Data][x]
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving normal data. At this time, if the
data is data read mode, it indicates present status data. If
the data is data write mode, it returns the data of the PC
computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving abnormal data from non-viable
functions or communication errors.
Data 1: Illegal Code
2: Not supported function