10-2-18 Current sensor error/Input current sensor error
Indoor display
3-LED DISPLAY
LED1
LED2
Outdoor display
LED ON
LED BLINKING
1. Checklist :
1) Is the PFC Shunt("A") resistance value correct? Check the resistor is opened
2) Is the IPM Shunt("B") resistance value correct? Check the resistor is opened
3) Is there no short or open around "C"?
2. Troubleshooting procedure
Restart after power off.
Is the PFC shunt and IPM
shunt resistance value correct?
Is the current sensor error appeared again?
Exchange the Outdoor PBA
Samsung Electronics
7-SEG DISPLAY
LED3
LED OFF
YES
YES
E462
AC Input I_Limit Trip Error
Current sensor error
Input current sensor error
MODEL
"A"
DB92-02866A
R426,R425
DB92-02867A
R063,R064,R065
NO
Exchange the Outdoor PBA
NO
Terminate the service
DESCRIPTION
"B"
"C"
R410,R411,R412
IC451
R408,R409,R410
IC451
10-21