Reconnect the ground cable (Allen wrench), the thermal sensor, and two lamp power connectors.
22.
[43] Cable, Sensor and Power Connectors
[43] Cable, Sensor and Power Connectors
Close the gantry doors.
23.
Turn the printer power ON.
24.
In order to track lamp usage and to estimate lamp replacement schedules, always re-set the usage statistics after
Note:
replacing a lamp bulb.
Re-set the Lamp Usage Statistics
In the Operator/Maintenance menu press the MENU button until you see Lamp Usage.
1.
Press ACCEPT to enter the Lamp Usage menu. Press MENU until you see "reset lamp usage".
2.
Press ACCEPT to see "reset lamp usage: lamp B". If you have changed the Blot side lamp, press ACCEPT. If you changed
3.
the Carriage side lamp, press the + or - key to select lamp C, then press ACCEPT.
Press ACCEPT one more time and the lamp use time and number of strikes will be re-set to zero.
4.
Error Handling and Troubleshooting