6. PILOT/A.S.D. ASSEMBLY
WARNING: The A.S.D. pilot assembly should not be
adjusted in any way. The A.S.D. shall not be altered so
that it will not operate or bypassed in any way. The
thermocouple cannot be changed as an individual
component.The complete assembly must be replaced in
the event of one or other component failure(s).
Only use a Genuine Baxi Spare Part.
Undo the screw retaining the pilot shield, and remove the
shield. Pull back the sleeve and disconnect the lead from
the electrode. Undo the nut on the pilot feed pipe.
Remove the screw holding the assembly to the
bracket. Undo the thermocouple from the gas tap.
Remove the assembly from the fire.
On re-assembly, shape the thermocouple in a similar
manner to the original.
7. ELECTRO-MAGNET UNIT
(a) Remove the gas tap as explained in 1(b).
(b) Remove the electro-magnet retaining nut and
withdraw the electro-magnet unit.
8. PIEZO UNIT
(Fig.12)
Pull off the plastic cap and disconnect the spark electrode
lead from the piezo unit. Undo the tabs on the rear of the
piezo unit and remove. Replace the piezo unit twisting the
tabs to retain it firmly in position. Re-connect the spark
electrode lead and re-fit the plastic cap.

9. LIGHT SWITCH

Caution: Ensure electrical supply is isolated.
Pull off the two flag terminals from the switch. Press
together the retaining arms on the rear of the switch and
remove the switch. Replace the switch and terminals, see
illustrated wiring diagram.
10. RESISTOR
(a) Check that the electrical supply is isolated.
(b) Remove the two screws securing the light bulb cover
and lift upwards.
(c) Remove the clip securing the resistor to the cover and
disconnect the 2 wires.
(d) Replace the resistor and reassemble in reverse order.
Electrical Supply 230V 50H z 110W.

Appliance Details

B
GF3 S
ERMUDA
UPER
(see Site Requirements
for clearances)
B
LFE5 S
ERMUDA
UPER
(see Site Requirements
for clearances)
H
I
(G
)
EAT
NPUT
ROSS
H
O
EAT
UTPUT
G
G
AS
ROUP
I
S
GF3
NJECTOR
IZE
LFE5
S
P
GF3
ETTING
RESSURE
(Cold)
S
P
LFE5
ETTING
RESSURE
(Cold)
T
O
HERMOCOUPLE
UTPUT
P
A
GF3
ILOT
SSY
LFE5
H
I
(G
)
EAT
NPUT
ROSS
Supplied By www.heating spares.co Tel. 0161 620 6677
(Fig. 12a)
(Figs 10 & 12)
Height - 706mm (to hearth)
Width - 750mm
Depth - 326mm
Weight - 35.8kg (unpacked)
Height - 713mm
Width - 915mm
Depth - 301mm
Weight - 39.1kg (unpacked)
5.70kW (19,450 Btu/h)
3.69kW (12,590 Btu/h)
G20 (Natural Gas)
230 F11
F13
14.5 + 0.5mbar
(5.8 + 0.2in wg)
13.8 + 0.5mbar
(5.5 + 0.2in wg)
9.4 - 13mV
9402
9401
210W (715 Btu/h)
Glass Front Panel
Sealing Rope
Glass Front Panel
Retaining Clamps
Burner Securing
Screws (2 off)
Coal Bed Locating
Pins (2 off)
Pilot Shield
Fig. 11 Coal Bed
Igniter
Retaining
Screws
Fig. 12 Gas Control Tap/Flame Failure Device
Controls Cover Panel
GF3 Super
Fig. 13 The Fire
Controls Cover Panel
LFE5 Super
page 9
Rope Seal
Retaining Barbs
Glass Front
Panel
Support Bar
Spark
Electrode
Pilot &
Thermocouple
F.F.D./Electro-Magnet Unit
Gas Tap Body
with Plug
Piezo Igniter
Fig. 12a
Gas Control
Knob
Gas Control
Knob