  • Page 1 14Fi AM Blue 17Fi AM Blue USER AND INSTALLATION INSTRUCTIONS Made in Italy...
  • Page 2 Proposta 1 - Pantone 431C Turn the control knob to the right to increase the temperature and to the left to decrease it (temperature between 37 and 60°C). Innovita-Scaldabagno stagno-BAXI 7-04-2015 I N D U S T R I A L...
  • Page 3 The energy label carries the information regarding the product’s energy efficiency characteristics. In this way the end consumer can identify and compare similar products and can make informed choices regarding high efficiency appliances. 14Fi AM Blue 17Fi AM Blue kWh/annum GJ/annum...
  • Page 4: Table Of Contents

    WARNING A number of symbols are used In some parts of the manual: This manual contains data and information for both the user and ATTENTION = for actions that require particular care and the installer. adequate preparation Specifically, the user must pay attention to the chapters: General warnings and safety devices, Control panel and Use of PROHIBITED = for actions that MUST NOT be performed the appliance.
  • Page 5: The Appliance

    GENERAL WARNINGS AND SAFETY DEVICES The instruction manual is an integral part of the product and must Contact with hot water and a temperature ≥50 ° C can cau- therefore be carefully stored and always accompany the appliance; se severe burns. in case of loss or damage, request another copy from the Technical Service Centre.
  • Page 6: Water Heater Components

    Water heater components Legend 1. Gas valve 2. Limit thermostat 3. NTC probe 4. Ignition/detection electrode 5. Fan 6. Heat exchanger 7. Burner 8. Flowmeter 9. DHW input 10. Gas 11. DHW output Fig. 1 - Water heater components...
  • Page 7: Replacement Of The Electrode

    Replacement of the electrode After the replacement of the electrode, ensure that the distance between the electrode and the burner is 6,5 mm. (tolerance 6,0÷7,0 mm). Fig. 2 - Replacement of the electrode Size and distances between hydraulic connections Measurements in mm 3 8 5 2 2 2 2 3 5...
  • Page 8: Wiring Diagram

    Wiring diagram Legend Blu - blue EL Electrode ignition Marrone - brown TR Ignition transformer Viola - violet F Fan Grigio - grey FX Domestic water flowmeter Nero - black LT Limit thermostat Rosso - red SP Domestic water probe Bianco - white GV Gas valve Azzurro - light blue...
  • Page 9: Technical Data

    Technical data 14Fi AM Blue 17Fi AM Blue kW - kcal/h kW - kcal/h Nominal heat input (Qn) 27,0 - 23.220 33,0 - 28.380 Nominal output power (Pn) 24,0 - 20.640 29,4 - 25.280 Minimum heat input (Qm) 4,5 - 3.870 5,6 - 4.820...
  • Page 10: Installation

    INSTALLATION Support bracket Having established the 1 6 7 Regulations position of the appliance, drill no. 2 Ø 6 holes to 1 0 5 apply the support bracket Entrust installation of the water heater to personnel with ap- (use the same bracket to propriate professional qualifications mark the holes).
  • Page 11: Water Connection

    remove any residue. Connect the water heater to the gas pipe of Pipes should not be in contact or near flammable mate- the internal system and fit upstream from the appliance a valve for rials and should not cross flammable walls or flammable gas interception and opening.
  • Page 12 7 ø 45 TYPE B22 Open chamber and forced draught for indoor from 7 to 13 ø 47 14Fi AM Blue from 13 to 25 not installed 1,3 m 1,8 m up to 4 ø 46...
  • Page 13 N.B. In the case of pipes with different lengths, see the graphs below. 14Fi AM Blue Flange flues not installed No flangia fumo (80 Pa) Flange flues ø 47 mm Flangia fumo ø 47 mm (60 Pa) Flange flues ø 45 mm Flangia fumo ø...
  • Page 14: Warnings Before Ignition

    Warnings before ignition Please remember that appliance installation, first ignition, mainte- nance and repairs must be performed by qualified personnel. Before turning on the appliance, proceed with suitable checks: - Ensure the gas system seal is good (according to current regula- tions) - Make sure mains data match those stated on the data plate - Make sure the installation meets current local regulations...
  • Page 15 Change parameter 02 (Gas type) - Press the reset button until the display shows MENU’ flashing to get out of the setting mode; press again the reset button until the Start-up the appliance and access in the Parameters menu display shows MENU’ flashing to get out of the MENU’ SERVICE - With water heater powered on, hold down the reset button - Disconnect the omni-polar switch outside the water heater for 10 for about 10 seconds, the display symbols start to flash, first the...
  • Page 16: Control Panel

    2. The type of gas for which the water heater was designed: (G20) - (G30) - (G31) Low Emission product 4. Model: (14Fi AM Blue) - (17Fi AM Blue) With the first ignition procedure completed, the display shows the symbols (Fig. 19). Press the button...
  • Page 17 Proposta 1 - Pantone 431C Switching off the appliance Innovita-Scaldabagno stagno-BAXI 7-04-2015 I N D U S T R I A L D E S I G N Hold down for about 5 seconds the water heater power off but-...
  • Page 18 Domestic water NTC fault alarm IN-OUT Request the assistance of a qualified technician. Permanent shutdown Parasitic flame alarm Request the assistance of a qualified technician. Temporary shutdown Interrupted modulator cable alarm Press and hold the reset button . As soon as the letters appear on the display, release the button.
  • Page 19 Hold down the reset button to confirm the selection. Proposta 1 - Pantone 431C Innovita-Scaldabagno stagno-BAXI 7-04-2015 To exit the “SERVICE MENU” press the reset button until I N D U S T R I A L D E S I G N the word “MENU”...
  • Page 20 Domestic hot water modulation with flow meter 0 = modulation without flow meter 0 - 1 1 = modulation with flow meter Water heater flow rate 10 = 14Fi AM Blue 10 - 11 depending on the model 11 = 17Fi AM Blue Modulator reactivity...
  • Page 21 Proposta 1 - Pantone 431C Info menu Innovita-Scaldabagno stagno-BAXI 7-04-2015 This feature allows displaying: I N D U S T R I A L D E S I G N...
  • Page 22: Maintenance

    MAINTENANCE Qualified personnel should inspect the appliance following the law in force, this is to ensure correct, continuous and reliable operation of the water heater. Insufficient or inadequate maintenance can compro- mise the safety of the appliance. Before carrying out any cleaning or maintenance, switch off the appliance using the omni-polar switch on the power supply line and close the gas and water valves to the appli- ance...
  • Page 23 Dismantling the heat exchanger (Fig. 31) Remove the casing and the burner by referring to the specific par- agraph. Disconnect the cold water inlet pipe. Remove the fixing screws of the heat exchanger and remove it. Fig. 30b - Dismantling burner Fig.

This manual is also suitable for: