2. Check that ALL connections are tested
with a propane leak detector (or soapy
water) solution.
3. Open the main valve slowly to avoid a fast
rush of propane to the excess flow valve
causing
propane
experience a propane "freeze-up," close
the main valve and wait at least fifteen
(15) minutes before trying again. Refer to
the regulator OEM operator's manual.
4. Listen carefully - a "hissing" sound longer
than one second may indicate a propane
leak. If you feel there may be a leak
present, close the valve and contact your
dealer or qualified propane technician for
repair assistance.
Replace all protective covers and caps on the
propane system after filling. Make sure the
valve is closed and the compartment door is
securely latched.
Propane container overfill
Never overfill your propane container above
the liquid capacity indicated on the container.
If a container is overfilled, liquid gas may flow
through the gas regulator, causing it to freeze
and/or introduce dangerous excessive gas
pressure into the lines. In addition, an
overfilled container placed in hot sunlight may
expel excessive gas through the relief valve
and be susceptible to ignition by any nearby
open flame or spark.
If you do overfill the propane container,
contact your dealer or a qualified propane
technician for assistance immediately. Do not
attempt to service a propane container overfill
yourself.
Maintenance
Propane gas is normally non-corrosive - you
need not worry about the inside of your
container. However, the outside should be
kept free from rust by a periodic coat of paint
in a light reflective color. Rust, scratches
and/or dents can affect the safety of the
cylinder. Inspect the cylinder at regular
intervals. If there is a problem, have it
evaluated by a qualified technician and
discard it. DOT requires that a visual
inspection be made prior to each filling.
freeze
up.
If
you
PROPANE SYSTEM
Any cylinder that has been exposed to fire,
leaks or seems damaged should not be
refilled. Do not attempt to repair any
containers, container valves, regulator or
appliances by yourself. Use only trained
certified propane gas service technicians to
perform repairs.
Propane cylinder recertification
If you have an older RV you should know that,
according to Federal law, DOT cylinders may
only be used for 12 years after their
manufacture date (the number of years for
certification may vary in your area). After that,
the cylinders must be "recertified" which
provides another five years of use. The
cylinders can be recertified every five years
thereafter. Federal DOT (Department of
Transportation) regulations require periodic
inspections
and
re-qualifications
propane cylinders. DO NOT USE damaged or
rusted containers.
Verify with your local propane dealer that all
required inspections and certifications have
been completed on the propane cylinder
within the correct time period before refilling
the cylinder.
P
R
ROPANE
EGULATOR
Propane
regulators
installed with the regulator vent facing
downward. Regulators that are not located
in baggage compartments have been
equipped with a protective cover. Make
sure the regulator vent faces downward
and (if applicable) the cover is in place to
minimize vent blockage that could result in
excessive gas pressure causing fire or
explosion.
Have the LP system checked for leakage
each time a cylinder is refilled or after any part
of
the
propane
disconnected.
The two-stage regulator has the only moving
components in the propane system. Its sole
function is to reduce the pressure from the
propane containers to a safe and consistent
SECTION 8
of
the
must
always
be
system
has