Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug refrigerator or disconnect power.
2.
Turn off the water supply to the refrigerator.
3.
Remove the water tubes from the valve
4.
Release the water tubes from the John
Guess fittings and remove.
REMOVING THE WATER VALVE
5.
Release the retainer tabs on the left and
right side of the valve as you pull down
on the valve.
6.
Drop the valve down and remove the in-
let water tube.
4-11