LG ARTCOOL LA090CP Product Manual page 20

Ductless air conditioning systems, mini-split, flex multi split, floor standing, ceiling cassette, ptac
Hide thumbs Also See for ARTCOOL LA090CP:
Table of Contents

Advertisement

Type
Mini-Split
A/C
Standard
A/C
Single Zone
A/C
A/C
A/C
H/P
H/P
H/P
H/P
H/P
All equipment single phase.
NOTE: Recommend shielded cable for low voltage wiring.
Please see local electrical codes for proper wire specifications.
Type
Mini Split
A/C
Standard
A/C
Single Zone
A/C
A/C
A/C
H/P
H/P
H/P
H/P
H/P
***Each system is pre-charged with enough refrigerant to charge 25 ft. of line and the interior unit.
NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement
installations) have the following additional requirement:
For systems with elevation of 25 ft. (see figure A), refrigerant lines must be oil trapped
between 8 ft. and 12 ft. of elevation.
For systems with elevation of greater than 25 ft. Refrigerant lines must be oil trapped at
least every 12 ft. of elevation.
* Each system should have a 6-8 inch inverted trap at the condensing unit if mounted above
indoor unit.
ELECTRICAL &
Electrical Specifications
BTUs
System Model #
9,000
LS090CP
11,500
LS120CP
18,000
LS180CP
22,500
LS240CP
LS302CP
28,000
LS090HP
9,800
LS120HP
11,500
LS180HP
19,500
LS240HP
22,500
LS302HP
28,000
Refrigerant Line & Formula Specifications***
System
Model #
BTUs
LS090CP
9,000
LS120CP
11,500
LS180CP
18,000
LS240CP
22,500
LS302CP
28,000
LS090HP
9,000
LS120HP
11,500
LS180HP
19,500
LS240HP
22,500
LS302HP
28,000
MINI-SPLIT STANDARD SINGLE ZONE
REFRIGERATION•
Voltage
Indoor
Outdoor
36V DC
115
36V DC
115
36V DC
230/208
36V DC
230/208
36V DC
230/208
36V DC
115
36V DC
115
36V DC
230/208
36V DC
230/208
36V DC
230/208
***For LS180HP, LS240CP/HP, LS302CP/HP
Wire Size
Minimum AWG
Indoor/Outdoor Connecting Cable Shielded
Pipe size
Additional
Liquid
Suction
Refrigerant
1/4"
3/8"
0.25 oz./ft.
1/4"
1/2 "
0.25 oz./ft.
1/4"
1/2 "
0.25 oz./ft.
1/4"
5/8"
0.25 oz./ft.
1/4"
5/8"
0.35 oz./ft.
1/4"
1/2"
0.25 oz./ft.
1/4"
1/2 "
0.25 oz./ft.
1/4"
5/8 "
0.25 oz./ft.
1/4"
5/8"
0.25 oz./ft.
1/4"
5/8"
0.35 oz./ft.
INDOOR UNIT
Figure A.
Example: 25 ft. maximum elevation.
Must install trap inverted.
QUICK REFERENCE
Rated
MCA*
MOP**
Amps
7.0
15
15
10.5
15
25
8.6/9.5
15
20
11.5/12.5
20
30
14.5/15.6
25
30
10.5
15
25
10.5
15
30
11.5/12.5
20
30
11.5/13.0
20
30
14.5/15.6
25
30
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
14-3
12-3***
18-4
Max. length
Max.
each pipe
elevation
25'
50'
25'
50'
50'
100'
50'
100'
50'
100'
25'
50'
25'
50'
50'
100'
50'
100'
50'
100'
OUTDOOR UNIT
OIL TRAP
25' maximum
8' minimum
12' maximum
17