Technical Data - Baxi Bermuda BBU 15 HE Installation & Servicing Instructions Manual

Condensing back boiler unit
Hide thumbs Also See for Bermuda BBU 15 HE:
Table of Contents

Advertisement

Sedbuk Declaration For Bermuda
The seasonal efficiency (SEDBUK) is 90.1%
This value is used in the UK Government's
Standard Assessment Procedure (SAP) for energy
rating of dwellings. The test data from which it has
been calculated has been certified by 0087.
10
© Baxi Heating UK Ltd 2010
Supplied By www.heating spares.co Tel. 0161 620 6677
BBU 15 HE

3.0 Technical Data

3.1
Bermuda HE CBBU 15 HE
Appliance Type
C
33
Appliance Category
CAT I
Inlet Pressure (Natural Gas - G20)
mbar
20
Injector (Natural Gas - G20)
420 (4.2 mm)
NO x Class
5 (31mg/kWh)
Heat Input (Net)
Max
kW
15.4
Heat Input (Gross)
Max
kW
17.1
Heat Output (Non-Condensing)
Max
kW
15.0
Heat Output (Condensing)
Max
kW
15.7
Boiler Set Temperature
Max
°C
75
Gas Rate
(Natural Gas - G20)
(After 10 mins)
Max
m
3
/h
1.63
Electrical Supply
230V~ 50H z
(Appliance must be connected to an
earthed supply)
Boiler Power Consumption
112W
Boiler Electrical Protection
IPX0
Boiler External Fuse Rating
3A
Connections
Gas Supply
-
15mm compression
Flow
-
22mm male copper
Return
-
22mm male copper
Weights
Packaged Boiler Carton
28 kg
Installation Lift Weight
27 kg
Flue Length
Max
Metres
12.5
Dimensions
Casing Height
Casing Width
Casing Depth
Firefront
See the instructions supplied with the firefront for
all Technical Data
2H
Min
5.0
Min
5.7
Min
4.88
Min
5.25
Min
25
Min
0.54
Min
3.0
- 538mm
- 383mm
- 306mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents