Return To Service; Rv Generator Service Interval - Generac Power Systems 004766-0 Owner's Manual

Air-cooled recreational vehicle generators quietpact 50 and 70 50 hz frequency
Table of Contents

Advertisement

4. Attach a tag to the engine indicating the viscosity
and classification of the oil in the crankcase.
5. Remove the spark plug and pour two or three
tablespoons of clean, fresh engine oil into the
spark plug threaded openings. Reinstall and
tighten the spark plug.
6. Remove the battery and store it in a cool, dry
room on a wooden board. Never store the battery
on any concrete or earthen floor.
7. Clean and wipe the entire generator.

3.13.2 RETURN TO SERVICE

To return the unit to service after storage, proceed
as follows:
1. Check the tag on the engine for oil viscosity and
classification. Verify that the correct recommend-
ed oil is used in the engine (see Section 1.5.4,
Page 6). If necessary, drain and refill with the
proper oil.
2. Check the state of the battery. Fill all cells of
unsealed batteries to the proper level with distilled
water. DO NOT USE TAP WATER IN THE BAT-
TERY. Recharge the battery to 100 percent state of
charge, or, if defective, replace the battery.
3. Clean and wipe the entire generator.
4. Reconnect the battery. Observe battery polarity.
Damage may occur if the battery is connected
incorrectly.
5. Turn OFF all electrical loads. Add fuel if neces-
sary and then start the engine.
6. Allow the unit to warm up thoroughly.
7. Apply electrical loads to at least 50 percent of the
unit's rated wattage capacity.
8. When the engine is thoroughly warmed up, shut
it down.
9. Your generator is now ready for service.
QUIETPACT 50 and 70 Recreational Vehicle Generators
3.14 RV GENERATOR SERVICE
Quietpact 50/70
50 Hours ................................Clean Spark Arrestor
50 Hours (only)........................Retorque Head Bolts
100 Hours ..........................Change Engine Oil/filter
100 Hours ..................................Clean Air Pre-filter
100 Hours ................................Inspect Spark Plugs
250 Hours ............Replace Paper Air Filter Element
400 Hours ..................................Replace Fuel Filter
500 Hours................................Replace Spark Plugs
1st 50 Hours-then
every 500 Hrs. ..........................Adjust Valve Lash
Section 3 – Maintenance
INTERVAL
Generac
®
Power Systems, Inc. 15

Advertisement

Table of Contents
loading

This manual is also suitable for:

004767-0