Download Print this page

Dimplex Auvergne Log 2920 Installation And Operating Instructions

Focal point fire with optiflame elite incorporating 2kw fan heater

Advertisement

Quick Links

AUS/NZ
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Introduction
Installation Instructions
Firebox
Door
Controls
behind
here
Heat
outlet
Fig.1
Installation and
Operating Instructions
Focal Point Fire with Optiflame® Elite
incorporating 2kW Fan Heater
Model: Auvergne Log Model 2920.
This fire incorporates a flame effect which can be used without
heating, so that the comforting effect may be enjoyed at any
time of the year. The flame effect is provided by low wattage
motor and two 40 watt lamps. Using the flame effect on its
own, therefore, requires little electricity.
The controls are concealed behind the ash pan flap beneath
the firebox.
A choice of 1 kW or 2kW thermostatically
controlled heat output is provided by the fan heater, which is
concealed beneath the unit.
This model is designed to be free standing and is normally
positioned against a wall.
Ensure that all packing items are removed (read any warning
labels carefully).
Retain all packing until installation is complete
Glass
viewing
screen
Fig.2
Issue 2. 5/01/04
08/18720/0
.

Advertisement

loading

Summary of Contents for Dimplex Auvergne Log 2920

  • Page 1 Installation and Operating Instructions Focal Point Fire with Optiflame® Elite incorporating 2kW Fan Heater AUS/NZ Model: Auvergne Log Model 2920. Issue 2. 5/01/04 08/18720/0 IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE Introduction This fire incorporates a flame effect which can be used without heating, so that the comforting effect may be enjoyed at any time of the year.
  • Page 2 Preparation for use WARNING: THIS APPLIANCE MUST BE EARTHED This heater must be used on an AC ~ supply only and the voltage marked on the heater must correspond to the supply voltage. Important Safety Advice: When using electrical appliances, Basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following: •...
  • Page 3 Operation The controls are located behind the hinged ash pan flap (see Fig.3). A switch is in the ‘ON' position when the red indicator mark of the switch is visible. Connect the fire to your electricity supply. Flame Effect Press switch to the 'ON' position.
  • Page 4 Maintenance WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE. Lamp replacement To gain access to the lamps, open the firebox door, remove the two screws securing the fuel effect assembly (see Fig.5). Slide out the fuel effect assembly. (See Fig. 5). Carefully rotate the lamp anti-clockwise until it comes out of its holder (see Fig.