Potterton Promax FSB 30 HE Installation & Service Instructions Manual page 44

Floor standing fanned flue condensing boiler
Hide thumbs Also See for Promax FSB 30 HE:
Table of Contents

Advertisement

Control
Knob
Fig. 48
Plastic Button
Cover
Hinge open
PCB Housing
Blue (CN11) Jumper
Red (CN12) Jumper
44
© Baxi Heating UK Limited 2010
PCB Housing Securing
Screw
Fig. 49
15.0
Changing Components
15.6
PCB
(Figs. 48 & 49)
WARNING: The PCB Control and Fan
Assembly are 325 Vdc. Isolate system
controls before access.
1. Pull the control knob off the spindle and remove the
plastic button cover. Refit them onto the new PCB
(Fig. 48).
2. Remove the top right hand securing screw and swing
out the PCB housing. Remove the PCB cover and
disconnect the electrical plugs noting their positions
3. Remove the screw securing the PCB to the housing.
The PCB can be removed from the housing.
4. Ensure that the two jumpers are fitted to the new
PCB as shown (Fig. 49).
5. Reconnect the plugs, fit the new PCB to the housing
and reassemble in reverse order.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gold fsb 30 he

Table of Contents