Download Print this page
First Alert UL STD 217 User Manual
First Alert UL STD 217 User Manual

First Alert UL STD 217 User Manual

First alert ul std 217; ul std 2034 combination carbon monoxide & smoke alarm with voice & location

Advertisement

Quick Links

STEP BY STEP GUIDE TO PROGRAMMING
USER'S MANUAL
THIS ALARM
COMBINATION CARBON MONOXIDE
For First Time and When Changing Batteries
& SMOKE ALARM WITH VOICE & LOCATION
Action:
Features:
1. Insert batteries (2, AA
Separate sensors to detect
batteries).
smoke and CO; the two alarm
systems work independently
Voice with programmable
location
Separate audible and visual
signals to indicate alarm
levels of smoke or CO
Powered by two "AA" batteries
2. Press & Hold Test Button if
you would like to program the
Access door for easy battery
location or change the location
replacement
UL STD 217
of the Alarm. Release button
Model
CONFORMS TO
AND
after Alarm responds.
PC1200V
UL STD 2034
3. After you hear the location
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
of where you are placing the
This user's manual contains important information about your
Alarm, Press & Hold the Test
Button.
Combination Carbon Monoxide & Smoke Alarm's operation.
If you are installing this Alarm for use by others, you must leave
this manual—or a copy of it—with the end user.
Your Alarm has now been programmed for the location of your choice.
Available locations: Basement
M08-0469-011 K1 09/14 Printed in Mexico
Para el manual del usuario en español,
por favor visite www.firstalert.com.
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
WHAT YOU WILL SEE AND HEAR WITH THIS ALARM
Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Under Normal Operations
Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Step By Step Guide to Programming This Alarm . . . . . . . . . . . . . . . . 2
Voice: Silent
What You Will See and Hear With This Alarm . . . . . . . . . . . . . . . . 2
Horn: Silent
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Where to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
When You Test the Alarm
Where This Alarm Should NOT Be Installed . . . . . . . . . . . . . . . . . . 3
Voice: "Testing." "Warning, evacuate smoke in [Location, example:
How to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Optional Locking Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Horn: 3 beeps, pause, 3 beeps, voice
If Your Smoke/CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Power LED: Flashes Red
What To Do First–Identify The Type Of Alarm . . . . . . . . . . . . . . . . . 5
If the CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Voice: "Warning, evacuate carbon monoxide in [Location, example:
If the Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Using the Silence Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Horn: 4 beeps, pause, 4 beeps, voice
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
LED: Flashes Red
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
If Battery Becomes Low
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Voice: "Replace battery in [Location, example "Hallway"]."
What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Horn: chirps once a minute
Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . 7
Power LED: Flashes Green approximately once a minute
How Can I Protect My Family From CO Poisoning? . . . . . . . . . . . . . . 7
Regulatory Information For Smoke/CO Alarms . . . . . . . . . . . . . . . 7-8
If Alarm is Not Operating Properly
Regulatory Information for CO Alarms . . . . . . . . . . . . . . . . . . . . . . 7
Voice: "Detector error in [Location, example "Hallway"], please see
Regulatory Information for Smoke Alarms . . . . . . . . . . . . . . . . . 7-8
Recommended Locations for Smoke Alarms . . . . . . . . . . . . . . . 7-8
Horn: 3 chirps every minute
About Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
LED: Three Green flashes approximately once a minute
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
General Limitations Of Smoke/CO Alarms . . . . . . . . . . . . . . . . . . . . . 9
Alarm has reached its End of Life
Voice: "Detector error in [Location, example "Basement"], please
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
Horn: 5 chirps every minute
© 2014 BRK Brands, Inc. All rights reserved.
LED: Five Green flashes approximately once a minute
Distributed by BRK Brands, Inc.
Alarm Levels of CO are Detected
3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005 • www.firstalert.com
Voice: "Warning, evacuate carbon monoxide in [Location, example:
All First Alert
Smoke Alarms conform to regulatory requirements,
®
Horn: 4 beeps, pause, 4 beeps, voice*
including UL217 and are designed to detect particles of combus-
LED: Flashes Red
tion. Smoke particles of varying number and size are produced
*NOTE: If unit goes into CO alarm, the regular 4 beeps-brief pause
in all fires.
cycle will repeat for four minutes. After four minutes, the pause will
Ionization technology is generally more sensitive than photo-
increase to one minute.
electric technology at detecting small particles, which tend
to be produced in greater amounts by flaming fires, which
Smoke is Detected
consume combustible materials rapidly and spread quickly. Sources
Voice: "Warning, evacuate smoke in [Location, example:
of these fires may include paper burning in a wastebasket, or a
grease fire in the kitchen.
Horn: 3 beeps, pause, 3 beeps, voice
Photoelectric technology is generally more sensitive than
LED: Flashes Red
ionization technology at detecting large particles, which tend
to be produced in greater amounts by smoldering fires, which
Smoke Alarm is Silenced
may smolder for hours before bursting into flame. Sources of these
Voice: Silent.
fires may include cigarettes burning in couches or bedding.
Horn: Off
For maximum protection, use both types of Smoke Alarms on
each level and in every bedroom of your home.
LED: Flashes Red
INTRODUCTION
FIRE SAFETY TIPS
Follow safety rules and prevent hazardous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters
away from children; 3) Store flammable materials in proper containers;
4) Keep electrical appliances in good condition and don't overload
electrical circuits; 5) Keep stoves, barbecue grills, fireplaces and
chimneys grease- and debris-free; 6) Never leave anything cooking
on the stove unattended; 7) Keep portable heaters and open flames,
like candles, away from flammable materials; 8) Don't let rubbish
accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately
if they are not working properly. Smoke Alarms that do not work cannot
alert you to a fire. Keep at least one working fire extinguisher on every
floor, and an additional one in the kitchen. Have fire escape ladders or
other reliable means of escape from an upper floor in case stairs are
blocked.
BASIC SAFETY INFORMATION
• Dangers, Warnings, and Cautions alert you to important
operating instructions or to potentially hazardous situations.
Pay special attention to these items.
• This Smoke/CO Alarm is approved for use in single-family
residences. It is NOT designed for marine or RV use.
• This combination Smoke/Carbon Monoxide Alarm has two
separate alarms. The CO Alarm is not designed to detect fire
or any other gas. It will only indicate the presence of carbon
monoxide gas at the sensor. Carbon monoxide gas may be
present in other areas. The Smoke Alarm will only indicate
the presence of smoke that reaches the sensor. The Smoke
Alarm is not designed to sense gas, heat or flames.
• This Smoke/CO Alarm cannot operate without working
batteries. Removing the batteries for any reason, or failing
to replace the batteries at the end of their service life,
removes your protection.
• NEVER ignore any alarm. See "If Your Smoke/CO Alarm
Sounds" for more information on how to respond to an alarm.
Failure to respond can result in injury or death.
• The Silence Features are for your convenience only and will
not correct a problem. See "Using the Silence Features" for
details. Always check your home for a potential problem after
any alarm. Failure to do so can result in injury or death.
• Test this Smoke/CO Alarm once a week. If the Alarm ever fails
to test correctly, have it replaced immediately! If the Alarm is
not working properly, it cannot alert you to a problem.
• This product is intended for use in ordinary indoor locations
of family living units. It is not designed to measure CO
levels in compliance with Occupational Safety and Health
Administration (OSHA) commercial or industrial standards.
Individuals with medical conditions that may make them
more sensitive to carbon monoxide may consider using
warning devices which provide audible and visual signals
for carbon monoxide concentrations under 30 ppm. For
additional information on carbon monoxide and your medical
condition contact your physician.
1
INSTALLATION
WHERE TO INSTALL THIS ALARM
Minimum coverage for Smoke Alarms, as recommended by the
National Fire Protection Association (NFPA), is one Smoke Alarm
on every floor, in every sleeping area, and in every bedroom (See
Alarm Will Say:
"Regulatory Information For Smoke Alarms" for details on the NFPA
"Welcome, First Alert Carbon
recommendations).
Monoxide and Smoke Alarm."
For CO Alarms, the National Fire Protection Association (NFPA)
"No location programmed" if
recommends that a CO Alarm should be centrally located outside of
first time or "[Location, example:
each separate sleeping area in the immediate vicinity of the bedrooms.
"Hallway"] location programmed"
For added protection, install additional CO Alarms in each separate
when changing batteries.
bedroom, and on every level of your home.
"To select location, press and
NOTE: For added protection, install an additional Smoke/CO Alarm at
hold test button now."
least 15 feet (4.6 meters) away from the furnace or fuel burning heat
"To save location, press and
source where possible. In smaller homes or in manufactured homes
hold test button after location is
where this distance cannot be maintained, install the Alarm as far away
heard." Alarm will speak list of
as possible from the furnace or other fuel burning source. Installing the
locations (see below).
Alarm closer than 15 feet (4.6 meters) will not harm the Alarm, but may
increase the frequency of unwanted alarms.
In general, install combination Smoke and Carbon Monoxide
"[Location, example: "Hallway"]
Alarms:
location saved."
On every level of your home, including finished attics and
If no location is chosen: "No
basements.
location saved."
Inside every bedroom, especially if people sleep with the door
partly or completely closed.
Hallway
In the hall near every sleeping area. If your home has multiple
Office
Child's Bedroom
sleeping areas, install a unit in each. If a hall is more than 40 feet
Kitchen
Utility Room
(12 meters) long, install a unit at each end.
Dining Room
Living Room
At the top of first-to-second floor stairs.
Family Room
Master Bedroom
At the bottom of the basement stairs.
Guest Bedroom
No Location
For additional coverage, install Alarms in all rooms, halls, and
storage areas, where temperatures normally remain between 40˚ F
and 100˚ F (4.4˚ C and 37.8˚ C).
Power LED: Flashes Green once a
RECOMMENDED PLACEMENT
minute
SMOKE ALARMS, CO ALARMS, AND COMBO UNITS
"Hallway"]. Evacuate."
followed by
"Hallway"]. Evacuate."
In new construction AC and AC/DC smoke alarms MUST
be interconnected to meet NFPA recommendations.
Repeated every 5 hours
When installing on the wall, the top edge of Smoke Alarms should
be placed between 4 inches (102 mm) and 12 inches (305 mm)
from the wall/ceiling line.
When installing on the ceiling, place the alarm as close to the
center as possible.
manual." Repeated every 5 hours
In either case, install at least 4 inches (102 mm) from where the
wall and ceiling meet. See "Avoiding Dead Air Spaces" for more
information.
NOTE: For any location, make sure no door or other obstruction could
keep carbon monoxide or smoke from reaching the Alarm.
see manual." Repeated every 5 hours
Installing Smoke/CO Alarms in Mobile Homes
For minimum security install one Smoke/CO Alarm as close to each
sleeping area as possible. For more security, put one unit in each room.
Many older mobile homes (especially those built before 1978) have little
or no insulation. If your mobile home is not well insulated, or if you are
unsure of the amount of insulation, it is important to install units on
"Hallway"]. Evacuate." "____ ppm."
inside walls only.
WHERE THIS ALARM SHOULD NOT BE INSTALLED
Do NOT locate this Smoke/CO Alarm:
In garages, furnace rooms, crawl spaces and unfinished attics.
Avoid extremely dusty, dirty or greasy areas.
Where combustion particles are produced. Combustion particles
"Hallway"]. Evacuate."
form when something burns. Areas to avoid include poorly ventilated
kitchens, garages, and furnace rooms. Keep units at least 20 feet
(6 meters) from the sources of combustion particles (stove, furnace,
water heater, space heater) if possible. In areas where a 20-foot
CO Alarm is Silenced
(6 meter) distance is not possible – in modular, mobile, or smaller
Voice: Silent.
homes, for example – it is recommended the Smoke Alarm be
Horn: Off
placed as far from these fuel-burning sources as possible. The
placement recommendations are intended to keep these Alarms at
LED: Flashes Red
a reasonable distance from a fuel-burning source, and thus reduce
"unwanted" alarms. Unwanted alarms can occur if a Smoke Alarm
is placed directly next to a fuel-burning source. Ventilate these
areas as much as possible.
Within 5 feet (1.5 meters) of any cooking appliance. In air streams
near kitchens. Air currents can draw cooking smoke into the smoke
sensor and cause unwanted alarms.
In extremely humid areas. This Alarm should be at least 10 feet
(3 meters) from a shower, sauna, humidifier, vaporizer, dishwasher,
laundry room, utility room, or other source of high humidity.
In direct sunlight.
In turbulent air, like near ceiling fans or open windows. Blowing air
may prevent CO or smoke from reaching the sensors.
In areas where temperature is colder than 40˚ F (4.4˚ C) or hotter
than 100˚F (37.8˚ C). These areas include non-airconditioned crawl
spaces, unfinished attics, uninsulated or poorly insulated ceilings,
porches, and garages.
In insect infested areas. Insects can clog the openings to the
sensing chamber.
Less than 12 inches (305 mm) away from fluorescent lights.
Electrical "noise" can interfere with the sensor.
In "dead air" spaces. See "Avoiding Dead Air Spaces".
AVOIDING DEAD AIR SPACES
"Dead air" spaces may prevent smoke from reaching the Smoke/CO
Alarm. To avoid dead air spaces, follow installation recommendations
below.
On ceilings, install Smoke/CO Alarms as close to the center of the
ceiling as possible. If this is not possible, install the Smoke/CO Alarm
at least 4 inches (102 mm) from the wall or corner.
For wall mounting (if allowed by building codes), the top edge of
Smoke/CO Alarms should be placed between 4 inches (102 mm) and
12 inches (305 mm) from the wall/ceiling line, below typical "dead air"
spaces.
On a peaked, gabled, or cathedral ceiling, install first Smoke/CO
Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured
horizontally. Additional Smoke/CO Alarms may be required depending
on the length, angle, etc. of the ceiling's slope. Refer to NFPA 72 for
details on requirements for sloped or peaked ceilings.
2
HOW TO INSTALL THIS ALARM
This combination Smoke/CO Alarm was designed to be mounted
on the ceiling or wall. It is not a tabletop device. You must install this
device on the ceiling or wall as outlined below. Read "Where To Install
This Alarm" before starting.
PARTS OF THIS SMOKE/CO ALARM
2
3
1
2
SUGGESTED AREAS FOR INSTALLING
KEY:
Tools you will need: pencil, drill with 3/16" or 5mm drill bit,
SMOKE ALARMS
flathead screwdriver, hammer.
SMOKE ALARM WITH
SILENCE FEATURE
CO ALARMS
• Do not connect this unit to any other alarm or auxiliary device.
It is a single-station unit that cannot be linked to other
BOTH, OR COMBINATION
devices. Connecting anything else to this unit may prevent it
SMOKE/CO ALARMS
from working properly.
Suggested locations are based on
NFPA recommendations (NFPA 72
• Do not install this unit over an electrical junction box. Air
for Smoke Alarms and NFPA 720 for
currents around junction boxes can prevent smoke from
Carbon Monoxide Alarms). Always
refer to national and local codes
reaching the sensing chamber and prevent the unit from
before beginning any installation.
alarming. Only AC powered units are intended for installation
over junction boxes.
FOLLOW THESE SIMPLE STEPS:
1. Hold base firmly and twist the mounting bracket clockwise to
separate it from the base.
2. Hold the mounting bracket against the
ceiling (or wall) so the two
clusters of universal mounting holes are
aligned approximately at the 9:00 and 3:00
o'clock positions. See image. Choose one
of the
three sets of holes shown, A, B or C (see
image) and trace around one of the sets.
Be sure to choose a top and bottom slot
on opposite sides so you can rotate the
universal mounting bracket into position
later. This will make it easier in the future
to remove the mounting bracket without
completely removing the screws.
3. Put the unit where it won't get covered with dust when you drill the
mounting holes.
4. Using a 3/16" (5 mm) drill bit, drill a hole through the center of the
oval outlines you traced.
5. Insert the plastic screw anchors (in the plastic bag with screws)
into the holes. Tap the screw anchors gently with a hammer, if
necessary, until they are flush with the ceiling or wall.
6. Install the screws but do not tighten completely. Attach the
mounting bracket by aligning the screws in the open portion of
the universal mounting slots and rotating the bracket into place.
Tighten the screws until they are snug to secure the bracket.
Do not over tighten.
7. Install the batteries (included). Open the battery door. Match the
terminals on the ends of each battery with the terminals on the
unit. Match "+" to "+" and "-" to "-." Push the batteries in until they
snap securely and cannot be shaken loose. If the batteries are not
snapped in completely, the unit cannot receive battery power.
NOTE: After you install the batteries, the power indicator light may
flash. (If the unit alarms, the light will blink rapidly, and the horn will
repeatedly sound 3 beeps, pause, 3 beeps.)
8. Position the base of the Alarm over the mounting bracket and turn.
Turn the Alarm clockwise until the unit is in place.
9. Test the Alarm. See "Weekly Testing."
OPTIONAL LOCKING FEATURE
The optional locking feature is designed to prevent unauthorized removal
of the alarm. It is not necessary to activate the lock in single-family
households where unauthorized alarm
removal is not a concern.
Tools you will need: Needle-nose
pliers or utility knife • Standard flathead
screwdriver
The feature uses a locking pin which is
molded into the mounting bracket. Remove
locking pin by using needle-nose pliers or
a utility knife.
To permanently remove the locking pin, insert a flathead screwdriver
between the locking pin and the lock and pry the pin out of the lock.
TO LOCK THE MOUNTING BRACKET
1. Using needle-nose pliers, detach the pin from the
mounting bracket.
2. Insert the locking pin through the hold on the
back of the smoke alarm as shown in
the diagram.
3. When you attach the alarm to the
mounting bracket the locking pin's head
will fit into a notch on the bracket.
TO UNLOCK THE MOUNTING BRACKET
1. Insert a flathead screwdriver in between the
mounting bracket and the locking pin.
2. Pry the alarm away from the bracket by
pushing up the screwdriver and turning the alarm counterclockwise (left) at
the same time.
3
IF YOUR SMOKE/CO ALARM SOUNDS
WHAT TO DO FIRST–IDENTIFY THE TYPE OF ALARM
Type of Alarm
What You See and Hear
Carbon Monoxide (CO)
Voice: "Warning, evacuate carbon
Horn: 4 beeps, pause, 4 beeps,
1
Test/Silence Button
2
Dual Power indicator light
LED: Flashes Red
and Alarm indicator:
Green LED provides visual
Smoke
Voice: "Warning, evacuate smoke
indication of an Alarm
Memory condition;
Red LED provides visual
Horn: 3 beeps, pause, 3 beeps,
indication of an Alarm and
Hush modes
LED: Flashes Red
3
Speaker
IF THE CO ALARM SOUNDS
"ALARM-MOVE TO FRESH AIR"
If you hear the CO alarm horn and the CO red light is flashing,
move everyone to a source of fresh air.
DO NOT remove the batteries!
1
Mounting bracket
Actuation of your CO Alarm indicates the presence of carbon
2
Mounting slots
monoxide (CO) which can kill you. In other words, when your CO
1
Alarm sounds, you must not ignore it!
3
Turn this way to remove
4
4
Turn this way to attach
IF THE CO ALARM SIGNAL SOUNDS:
5
Battery door, install
1. Press the Test/Silence button.
batteries here
2. Call your emergency services, fire department or 911. Write down
the number of your local emergency service here:
_____________________________________________________________
3
3. Immediately move to fresh air—outdoors or by an open door or
window. Do a head count to check that all persons are accounted
for. Do not re-enter the premises, or move away from the open door
or window until the emergency services responder has arrived, the
premises have been aired out, and your CO Alarm remains in its
normal condition.
4. After following steps 1-3, if your CO Alarm reactivates within a
24-hour period, repeat steps 1-3 and call a qualified appliance
technician to investigate for sources of CO from fuel-burning
equipment and appliances, and inspect for proper operation of this
equipment. If problems are identified during this inspection have the
equipment serviced immediately. Note any combustion equipment
not inspected by the technician, and consult the manufacturers'
instructions, or contact the manufacturers directly, for more
information about CO safety and this equipment. Make sure that
motor vehicles are not, and have not, been operating in an attached
garage or adjacent to the residence. Write down the number of a
qualified appliance technician here:
_____________________________________________________________
NOTE: A qualified appliance technician is defined as "a person, firm,
corporation, or company that either in person or through a
representative, is engaged in and responsible for the installation,
Mounting Hole Sets
testing, servicing, or replacement of heating, ventilation, air conditioning
(HVAC) equipment, combustion appliances and equipment, and/or gas
fireplaces or other decorative combustion equipment."
A
C
AFTER AN ALARM
B
B
After the emergency responders arrive, the premises aired out, and
C
A
your CO Alarm remains in its normal condition, you can check what
the highest carbon monoxide level sensed was:
Action:
Alarm Will Say:
1. Press & Hold Test Button
"Highest carbon monoxide level
was ___ ppm. Please see manual."
"To clear highest carbon monoxide
level, press and hold test button
now."
2. Press & Hold Test Button, if you
"Highest carbon monoxide level
would like to clear the highest
cleared."
level sensed.
If you would like to keep the
Alarm will say nothing.
highest level in memory, do not
press anything.
IF THE SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
If the unit alarms and you are not testing the unit, it is warning
you of a potentially dangerous situation that requires your
immediate attention. NEVER ignore any alarm. Ignoring the
alarm may result in injury or death.
Never remove the batteries from a battery operated Smoke/CO
Alarm to stop an unwanted alarm (caused by cooking smoke,
etc.). Removing batteries disables the alarm so it cannot sense
smoke, and removes your protection. Instead open a window
or fan the smoke away from the unit. The alarm will reset
automatically.
If the unit alarms get everyone out of the house immediately.
WHAT TO DO IN CASE OF FIRE
• Don't panic; stay calm. Follow your family escape plan.
• Get out of the house as quickly as possible. Don't stop to get
Locking Pin
dressed or collect anything.
• Feel doors with the back of your hand before opening them. If a
door is cool, open it slowly. Don't open a hot door. Keep doors
and windows closed, unless you must escape through them.
• Cover your nose and mouth with a cloth (preferably damp).
Take short, shallow breaths.
• Meet at your planned meeting place outside your home, and
do a head count to make sure everybody got out safely.
• Call the Fire Department as soon as possible from outside.
Give your address, then your name.
• Never go back inside a burning building for any reason.
• Contact your Fire Department for ideas on making your home
safer.
Alarms have various limitations. See "General Limitations of
Smoke/CO Alarms" for details.
USING THE SILENCE FEATURES
Never remove the batteries to quiet an unwanted alarm. Removing
the batteries disables the alarm and removes your protection.
The Silence Feature is intended to temporarily silence the horn while
you identify and correct the problem. Do not use the Silence Feature
in emergency situations. It will not correct a CO problem or extinguish
a fire.
The Silence Feature can temporarily quiet an unwanted alarm for several
minutes. You can silence this Smoke/CO Alarm by pressing the Test/
Silence button on the alarm cover for at least 3-5 seconds.
After the Test/Silence button is released, the Red LED blinks during the
silence mode.
When the Smoke Alarm is
When the CO Alarm is Silenced
Silenced
T
he Smoke Alarm will remain
The CO Alarm will remain silent
silent for up to 15 minutes, then
for up to 4 minutes.
return to normal operation.
After 4 minutes, if CO levels
If the smoke has not cleared–or
remain potentially dangerous the
continues to increase–the device
horn will start sounding again.
will go back into alarm.
4
5
SILENCING THE LOW BATTERY WARNING
This silence feature can temporarily quiet the low battery warning
"chirp" for up to 8 hours. You can silence the low battery warning
"chirp" by pressing the Test/Silence button on the alarm cover.
Once the low battery warning "chirp" silence feature is activated, the
unit continues to flash the Green light once a minute for 8 hours. After
8 hours, the low battery "chirp" will resume. Replace the batteries as
soon as possible; this unit will not operate without battery power!
monoxide in [Location,
example: "Hallway"].
To deactivate this feature: Press the Test/Silence button again. The
Evacuate." "____ ppm."
unit will go into Test Mode and the low battery warning will resume (LED
flashes and unit sounds "chirp" once a minute).
voice
SILENCING THE END OF LIFE SIGNAL
This silence feature can temporarily quiet the End of Life warning
"chirp" for up to 2 days. You can silence the End of Life warning "chirp"
in [Location, example:
by pressing the Test/Silence button. The horn will chirp, acknowledging
"Hallway"]. Evacuate."
that the End of Life silence feature has been activated.
After approximately 2 days, the End of Life "chirp" will resume.
voice
WEEKLY TESTING
NEVER use an open flame of any kind to test this unit. You
might accidentally damage or set fire to the unit or to your
home. The built-in test switch accurately tests the unit's
operation as required by Underwriters Laboratories, Inc. (UL).
NEVER use vehicle exhaust! Exhaust may cause permanent
damage and voids your warranty.
DO NOT stand close to the alarm when the horn is sounding.
Exposure at close range may be harmful to your hearing. When
testing, step away when horn starts sounding.
It is important to test this unit every week to make sure it is working
properly. Using the test button is the recommended way to test this
Smoke/CO Alarm.
You can test this Smoke/CO Alarm by pressing and holding the Test/
Silence button on the Alarm cover until Alarm Voice says "Testing"
(typically 3-5 seconds).
During testing, you will see and hear the following sequence:
• The Alarm Voice will say "Testing." The Horn will sound 3 beeps,
pause, 3 beeps. The Alarm Voice will say "Warning, evacuate
smoke in [Location, example: "Hallway"]. Evacuate." The Power
LED flashes Red.
• Next the Horn will sound 4 beeps, pause, 4 beeps. The Alarm
Voice will say "Warning, evacuate carbon monoxide in [Location,
example: "Hallway"]. Evacuate." The LED flashes Red.
If the unit does not alarm, make sure the batteries are correctly installed,
and test again. If the unit still does not alarm, replace it immediately.
REGULAR MAINTENANCE
This unit has been designed to be as maintenance free as possible, but
there are a few simple things you must do to keep it working properly.
Test it at least once a week.
Clean the Smoke/CO Alarm at least once a month; gently vacuum
the outside of the Smoke/CO Alarm using your household vacuum's
soft brush attachment. A can of clean compressed air (sold at
computer or office supply stores) may also be used. Follow
manufacturer instructions for use. Test the Smoke/CO Alarm. Never
use water, cleaners or solvents since they may damage the unit.
If the Smoke/CO Alarm becomes contaminated by excessive dirt,
dust and/or grime, and cannot be cleaned to avoid unwanted
alarms, replace the unit immediately.
Relocate the unit if it sounds frequent unwanted alarms.
See "Where This Alarm Should Not Be Installed" for details.
Choosing a replacement battery:
Your Smoke/CO Alarm requires two standard AA alkaline batteries.
The following batteries are acceptable as replacements: Eveready
Energizer E91 or Duracell MN1500. These batteries are available
at many local retail stores.
Always use the exact batteries specified by this User's Manual.
DO NOT use rechargeable batteries. Clean the battery contacts
and also those of the device prior to battery installation. Install
batteries correctly with regard to polarity (+ and -).
Please dispose of or recycle used batteries properly, following
any local regulations. Consult your local waste management
authority or recycling organization to find an electronics
recycling facility in your area. DO NOT DISPOSE OF BATTERIES
IN FIRE. BATTERIES MAY EXPLODE OR LEAK.
Keep battery out of reach of children. In the event a battery is
swallowed, immediately contact your poison control center,
your physician, or the National Battery Ingestion hotline at
202-625-3333 as serious injury may occur.
Actual battery service life depends on the Smoke/CO Alarm and the
environment in which it is installed. All the batteries specified above
are acceptable replacement batteries for this unit. Regardless of the
manufacturer's suggested battery life, you MUST replace the battery
immediately once the unit starts "chirping" (the "low battery warning").
WHAT YOU NEED TO KNOW ABOUT CO
WHAT IS CO?
CO is an invisible, odorless, tasteless gas produced when fossil fuels
do not burn completely, or are exposed to heat (usually fire). Electrical
appliances typically do not produce CO.
These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline,
kerosene, and propane.
Common appliances are often sources of CO. If they are not properly
maintained, are improperly ventilated, or malfunction, CO levels can
rise quickly. CO is a real danger now that homes are more energy
efficient. "Air-tight" homes with added insulation, sealed windows,
and other weatherproofing can "trap" CO inside.
SYMPTOMS OF CO POISONING
These symptoms are related to CO POISONING and should be
discussed with ALL household members.
Mild Exposure: Slight headache, nausea, vomiting, fatigue ("flu-like"
symptoms).
Medium Exposure: Throbbing headache, drowsiness, confusion, fast
heart rate.
Extreme Exposure: Convulsions, unconsciousness, heart and lung
failure. Exposure to Carbon Monoxide can cause brain damage, death.
This CO Alarm measures exposure to CO over time. It alarms if CO
levels are extremely high in a short period of time, or if CO levels reach
a certain minimum over a long period of time. The CO Alarm generally
sounds an alarm before the onset of symptoms in average, healthy
adults. Why is this important? Because you need to be warned of a
potential CO problem while you can still react in time. In many reported
cases of CO exposure, victims may be aware that they are not feeling
well, but become disoriented and can no longer react well enough to
exit the building or get help. Also, young children and pets may be the
first affected. The average healthy adult might not feel any symptoms
when the CO Alarm sounds. However, people with cardiac or respiratory
problems, infants, unborn babies, pregnant mothers, or elderly people
can be more quickly and severely affected by CO. If you experience
even mild symptoms of CO poisoning, consult your doctor immediately!
FINDING THE SOURCE OF CO AFTER AN ALARM
Carbon monoxide is an odorless, invisible gas, which often makes it
difficult to locate the source of CO after an alarm. These are a few of
the factors that can make it difficult to locate sources of CO:
• House well ventilated before the investigator arrives.
• Problem caused by "backdrafting."
• Transient CO problem caused by special circumstances.
Because CO may dissipate by the time an investigator arrives, it may
be difficult to locate the source of CO. BRK Brands, Inc. shall not be
obligated to pay for any carbon monoxide investigation or service
call.
6

Advertisement

loading

Summary of Contents for First Alert UL STD 217

  • Page 1 Voice: “Warning, evacuate carbon 8 hours, the low battery “chirp” will resume. Replace the batteries as Features: 1. Insert batteries (2, AA “Welcome, First Alert Carbon recommendations). soon as possible; this unit will not operate without battery power! monoxide in [Location, •...
  • Page 2 Warning: Changes or modifications to the product, not expressly periods between cycles). 911 or the Fire Department. Refer to “If The approved by First Alert / BRK Brands, Inc., could void the user’s CO Alarm Sounds” for details. • Negative pressure differential resulting from the use of exhaust authority to operate the equipment.

This manual is also suitable for:

Ul std 2034