Remote flashlight test smoke and fire alarm, with escape light feature

Advertisement

USER'S MANUAL
SMOKE AND FIRE* ALARM
REMOTE FLASHLIGHT TEST
SMOKE ALARM
IMPORTANT!
PLEASE READ CAREFULLY AND SAVE.
This user's manual contains important information about your Smoke
Alarm's operation. If you are installing this Smoke Alarm for use by
others, you must leave this manual-or a copy of it-with the end user.
M08-0024-000 J
07/02
THIS USER'S MANUAL HAS BEEN RESIZED TO PRINT OUT
ON 8-1/2 x 11" PAGES.

TABLE OF CONTENTS

Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Before You Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . .1
How To Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . .2
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If This Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
If You Suspect A Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Recommended Locations For Smoke Alarms . . . . . . . . . . . . . . .4-5
Locations To Avoid For Smoke Alarms . . . . . . . . . . . . . . . . . . . . . .5
About Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . .6
Limitations Of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
All Rights Reserved. © 2002 BRK Brands, Inc.
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005 • www.firstalert.com
*All First Alert
®
Smoke Alarms conform to regulatory requirements,
including UL217 and are designed to detect particles of combustion.
Smoke particles of varying number and size are produced in all fires.
Ionization technology is generally more sensitive than photoelectric
technology at detecting small particles, which tend to be produced
in greater amounts by flaming fires, which consume combustible
materials rapidly and spread quickly. Sources of these fires may
include paper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric technology is generally more sensitive than ionization tech-
nology at detecting large particles, which tend to be produced in
greater amounts by smoldering fires, which may smolder for hours
before bursting into flame. Sources of these fires may include
cigarettes burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each
level of your home.
REMOTE FLASHLIGHT TEST
SMOKE ALARM WITH ESCAPE
LIGHT
®
FEATURE
Model SA90B, SA150B

FIRE SAFETY TIPS

Follow safety rules and prevent hazardous situations: 1) Use smoking materi-
als properly. Never smoke in bed. 2) Keep matches or lighters away from chil-
dren; 3) Store flammable materials in proper containers;
4) Keep electrical appliances in good condition and don't overload electrical
circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys grease- and
debris-free; 6) Never leave anything cooking on the stove unattended; 7) Keep
portable heaters and open flames, like candles, away from flammable materi-
als; 8) Don't let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if they are
not working properly. Smoke Alarms that do not work cannot alert you to a fire.
Keep at least one working fire extinguisher on every floor, and an additional one
in the kitchen. Have fire escape ladders or other reliable means of escape from
an upper floor in case stairs are blocked.

BEFORE YOU INSTALL THIS SMOKE ALARM

IMPORTANT! Read "Recommended Locations for Smoke Alarms" and
"Locations to Avoid for Smoke Alarms" before beginning. This unit monitors
the air, and when smoke reaches its sensing chamber, it alarms. It can give
you more time to escape before fire spreads. This unit can ONLY give an
early warning of developing fires if it is installed, maintained and located
where smoke can reach it, and where all residents can hear it, as described
in this manual. This unit will not sense gas, heat, or flame. It cannot prevent
or extinguish fires.
Understand The Different Type of Smoke Alarms
Battery powered or electrical? Different Smoke Alarms provide
different types of protection. See "About Smoke Alarms" for details.
Know Where To Install Your Smoke Alarms
Fire Safety Professionals recommend at least one Smoke Alarm on every
level of your home, in every bedroom, and in every bedroom hallway or sepa-
rate sleeping area. See "Recommended Locations For Smoke Alarms" and
"Locations To Avoid For Smoke Alarms" for details.
Know What Smoke Alarms Can and Can't Do
A Smoke Alarm can help alert you to fire, giving you precious time to
escape. It can only sound an alarm once smoke reaches the sensor. See
"Limitations of Smoke Alarms" for details.
Check Your Local Building Codes
This Smoke Alarm is designed to be used in a typical single-family home. It
alone will not meet requirements for boarding houses, apartment buildings,
hotels or motels. See "Special Compliance Considerations" for details.
This unit will not alert hearing impaired residents. It is rec-
ommended that you install special units which use devices
like flashing strobe lights to alert the hearing impaired.
Do not connect this unit to any other alarm or auxiliary
device. It is a single-station unit that cannot be linked to
other devices. Connecting anything else to this unit may pre-
vent it from working properly.
Unit will not operate without battery power. The Smoke
Alarm cannot work until you install the battery in the correct
position (Match "+" to "+" and "-" to "-").
This Smoke Alarm has a battery guard which prevents it
from closing unless a battery is installed. This warns you the
unit will not operate without a battery.
Do not install this unit over an electrical junction box. Air cur-
rents around junction boxes can prevent smoke from reaching
the sensing chamber and prevent the unit from alarming. Only
AC powered units are intended for installation over junction
boxes.
Do not stand too close to the unit when the alarm is sound-
ing. It is loud to wake you in an emergency. Exposure to the
horn at close range may harm your hearing.
Do not paint over the unit. Paint may clog the openings to the
sensing chamber and prevent the unit from operating properly.
1

Advertisement

loading

Summary of Contents for First Alert SA150B

  • Page 1: Table Of Contents

    Regular Maintenance ........3 If This Smoke Alarm Sounds ......4 What To Do In Case Of Fire .
  • Page 2: How To Install This Smoke Alarm

    The Smoke Alarm may beep briefly when you install the battery—this is normal. Model SA150B has two batteries— one powers the alarm, the other powers the Escape Light®. You must reposition BOTH batteries. The Escape Light®...
  • Page 3: Weekly Testing

    Using the test button is the recommended way to test this Smoke Alarm. Press and hold the test button on the cover of the unit until the alarm sounds (the unit may continue to alarm for a few seconds after you release the button).
  • Page 4: If This Smoke Alarm Sounds

    Model SA150B will be free from defects in material and workmanship. In addition, BRK warrants that for a period of five years from the date of purchase, the Model SA90B will be free from defects in material and workmanship.
  • Page 5: Locations To Avoid For Smoke Alarms

    On ceilings, install Smoke Alarms as close to the center of the ceiling as possible. If this is not possible, install the Smoke Alarm at least 4 inches (102 mm) from the wall or corner. For wall mounting (if allowed by building codes), the top edge of Smoke Alarms should be placed between 4 and 12 inches (102 and 305 mm) from the wall/ceiling line, below typical “dead air”...
  • Page 6: About Smoke Alarms

    All these Smoke Alarms are designed to provide early warning of fires if located, installed and cared for as described in the user’s manual, and if smoke reaches them. If you are unsure which type of Smoke Alarm to install, refer to Chapter 2 of the National Fire Protection Association (NFPA) Standard 72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code).