First Alert SA4121C User Manual

Advertisement

Quick Links

User's Manual
Smoke Alarms
AC Powered Ionization Smoke Alarm
AC Powered Ionization Smoke Alarm
with Battery Back-Up and
Silence Feature
Cat. SA4121C, SA4121B
Input: 120V AC, 60Hz, 0.5A
Ionization smoke alarms are generally more effective at detecting flaming fires which
consume combustible materials rapidly and spread quickly. Sources of these fires may
include paper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric smoke alarms are generally more effective at detecting smoldering fires
which smolder for hours before bursting into flame. Sources of these fires may include
cigarettes burning in couches or bedding.
For maximum protection, use both types of smoke alarms on each level of your home.
M06-2071-002 6/00
INSIDE THIS MANUAL
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
This user's manual contains important information about your smoke alarm's operation. If you are installing
this smoke alarm for use by others, you must leave this manual—or a copy of it—with the end user.
THIS USER'S MANUAL HAS BEEN RESIZED TO PRINT OUT ON 8-1/2 x 11" PAGES.
BLACK page numbers reference the original printed document.
RED page numbers reference this web version.
Other Features Of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Limitations Of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Where To Install Smoke Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Where Not To Install Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Protecting Your Family From Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important! Read Before Installing This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How To Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If This Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using The Silence Feature (Smoke Alarms SA4121B and SA4121C Only) . . . . . . . . . . . . .
If This Smoke Alarm Is Not Working Properly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10-Year Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
All Rights Reserved. ©2000 BRK Brands, Inc.
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: Monday-Friday, 7:30am-5pm (Central Time): (800) 323-9005 • Internet: www.firstalert.com
OTHER FEATURES OF SMOKE ALARMS
Battery (DC) operated smoke alarms: Provide protection even when electricity fails, provided the batteries are fresh
and correctly installed. Units are easy to install, and do not require professional installation.
AC powered smoke alarms: Can be interconnected so if one unit senses smoke, all units alarm. They do not operate
if electricity fails. Units must be installed by a qualified electrician.
AC/DC powered smoke alarms: (AC with battery back-up): Can be interconnected so if one unit senses smoke,
all units alarm. They will operate if electricity fails, provided the batteries are fresh and correctly installed. Units must be
installed by a qualified electrician.
Smoke alarms for the hearing impaired: Special purpose smoke alarms should be installed for the hearing
impaired. They include a visual alarm and an audible alarm horn, and meet the requirements of the Americans With
Disabilities Act. These units can be interconnected so if one unit senses smoke, all units alarm. They do not operate if
electricity fails. Units must be installed by a qualified electrician. First Alert
powered unit that has an 85 decibel alarm and a 177 candela strobe light, which flashes rapidly when the unit is in
alarm.
All these units are designed to provide early warning of fires if located, installed and cared for as described in the user's
manual, and if smoke reaches them. If you are unsure which type of unit to install, refer to Chapter 2 of the National Fire
Protection Association (NFPA) Standard 72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code). National Fire
Protection Association, One Batterymarch Park, Quincy, MA 02269-9101. Local building codes may also require
specific units in new construction or in different areas of the home.
with Battery Back-up
SPECIAL COMPLIANCE CONSIDERATIONS
Cat. SA4120C, SA4120B
This smoke alarm alone is not a suitable substitute for complete fire detection systems in places housing many
Input: 120V AC, 60Hz, 0.5A
people—like apartment buildings, condominiums, hotels, motels, dormitories, hospitals, long-term health care facilities,
nursing homes, day care facilities, or group homes of any kind—even if they were once single-family homes. It is not a
suitable substitute for complete fire detection systems in warehouses, industrial facilities, commercial buildings, and
special-purpose non-residential buildings which require special fire detection and alarm systems. Depending on the
building codes in your area, this smoke alarm may be used to provide additional protection in these facilities.
The following information applies to all four types of buildings listed below: In new construction, most building
codes require the use of AC or AC/DC powered smoke alarms only. In existing construction, AC, AC/DC, or DC
powered smoke alarms can be used as specified by local building codes. Refer to NFPA 72 (National Fire Alarm Code)
or NFPA 101 (Life Safety Code), local building codes, or consult your Fire Department for detailed fire protection
requirements in buildings not defined as "households."
Model
SA4120B
1. Single-Family Residence: Single family home, townhouse. It is recommended smoke alarms be installed on every
SA4121B
level of the home, in every bedroom, and in each bedroom hallway.
2. Multi-Family or Mixed Occupant Residence: Apartment building, condominium. This smoke alarm is suitable for
use in individual apartments or condos, provided a primary fire detection system already exists to meet fire detection
requirements in common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not
provide sufficient warning to all residents or meet local fire protection ordinances/regulations.
3. Institutions: Hospitals, day care facilities, long-term health care facilities. This smoke alarm is suitable for use in
individual patient sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection
requirements in common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not
provide sufficient warning to all residents or meet local fire protection ordinances/regulations.
4. Hotels and Motels: Also boarding houses and dormitories. This smoke alarm is suitable for use inside individual
sleeping/resident rooms, provided a primary fire detection system already exists to meet fire detection requirements in
common areas like lobbies, hallways, or porches. Using this smoke alarm in common areas may not provide sufficient
warning to all residents or meet local fire protection ordinances/regulations.
LIMITATIONS OF SMOKE ALARMS
Smoke alarms have played a key role in reducing deaths resulting from home fires worldwide. However, like any warning
device, smoke alarms can only work if they are properly located, installed, and maintained, and if smoke reaches them.
They are not foolproof.
Smoke alarms cannot work without power. Battery operated units cannot work if the batteries are missing,
2/3
disconnected or dead, if the wrong type of batteries are used, or if the batteries are not installed correctly. AC units
2/3
cannot work if the AC power is cut off for any reason (open fuse or circuit breaker, failure along a power line or at a
2/3
power station, electrical fire that burns the electrical wires, etc.). If you are concerned about the limitations of battery or
3/4
AC power, install both types of units.
4/5
Smoke alarms cannot detect fires if the smoke does not reach them. Smoke from fires in chimneys or walls, on
4/5
roofs, or on the other side of closed doors may not reach the sensing chamber and set off the alarm. That is why one
4/5
unit should be installed inside each bedroom or sleeping area—especially if bedroom or sleeping area doors are closed
4/5
at night—and in the hallway between them.
4/5
4/6
Smoke alarms may not detect fire on another floor or area of the home. For example, a stand-alone unit on the
second floor may not detect smoke from a basement fire until the fire spreads. This may not give you enough time to
escape safely. That is why recommended minimum protection is at least one unit in every sleeping area, and every
bedroom on every level of your home. Even with a unit on every floor, stand-alone units may not provide as much
protection as interconnected units, especially if the fire starts in a remote area. Some safety experts recommend
installing interconnected AC powered units with battery back-up (see "Other Features Of Smoke Alarms") or professional
fire detection systems, so if one unit senses smoke, all units alarm. Interconnected units may provide earlier warning
1
smoke alarm model SA100B is an AC
®

Advertisement

loading

Summary of Contents for First Alert SA4121C

  • Page 1 Using The Silence Feature (Smoke Alarms SA4121B and SA4121C Only) ... . .
  • Page 2: Where Not To Install Smoke Alarms

    than stand-alone units since all units alarm when one detects smoke. AGENCY PLACEMENT RECOMMENDATIONS Smoke alarms may not be heard. Though the alarm horn in this unit meets or exceeds current standards, IMPORTANT! it may not be heard if: 1) the unit is located outside a closed or partially closed door; 2) residents recently This equipment should be installed in accordance with the National Fire Protection Association’s Standard 72.
  • Page 3: Protecting Your Family From Fire

    PROTECTING YOUR FAMILY FROM FIRE DANGER! • ELECTRICAL SHOCK HAZARD. Turn off power to the area where you will install this unit at the Putting up smoke alarms is one step in protecting your family from fires. You must also reduce the chance a fire will start circuit breaker or fuse box before beginning installation.
  • Page 4: How To Install This Smoke Alarm

    Interconnected units will only work if they are wired to compatible units and all During installation or testing, if you accidentally press the Silence button, the alarm will Cat. Nos. SA4121C and SA4121B: requirements are met.
  • Page 5: Weekly Testing

    • When the battery back-up becomes weak, the smoke alarm unit will “chirp” about once a minute (the low Smoke Alarms With Silence Feature Only: Cat. SA4121C and SA4121B: If the unit alarms and you are certain battery warning). This low battery warning should last for 7 days, but you should replace the battery imme- that the source of smoke is not a fire—cooking smoke or an extremely dusty furnace, for example—use the silence...
  • Page 6: 10-Year Limited Warranty

    10-YEAR LIMITED WARRANTY Coverage: BRK Brands, Inc. warrants its enclosed smoke alarm to be free from defects in materials and workmanship under normal use for a period of ten years from the date of purchase. During the first year after the date of purchase, BRK Brands, Inc.