DETAIL C
LEG DETAIL
2" (50.8MM) SCH 40
FEMALE THREADED
ADAPTER
2" (50.8MM) SCH 40
MALE THREADED
ADAPTER
Use additional 2" SCH 40 male threaded adapters
which can be threaded into the female threaded
adapters to make additional adjustments to the lev-
el of the unit.
Elevated Slab Mounting using Feet
Extenders
XC21
DETAIL D
Slab Side Mounting
#10 1/2" LONG SELF−DRILLING
SHEET METAL SCREWS
STABILIZING BRACKET (18 GAUGE
METAL
#10 1−1/4" LONG HEX HD SCREW
BASE
CONCRETE
ANCHORS (HOLE DRILL 1/4")
WOOD OR PLASTIC SLAB
(HOLE DRILL 1/8")
IMPORTANT
quire strapping the unit to the pad using brackets and anchors commonly
available in the marketplace.
Figure 5. Placement, Slab Mounting and Stabilizing Unit
2" WIDTH; HEIGHT AS
REQUIRED)
AND FLAT WASHER
SLAB
USE
TWO
PLASTIC
NO PLASTIC ANCHOR
Deck Top Mounting
STABILIZING BRACKET (18 GAUGE METAL
2"
(50.8MM)
WIDTH;
REQUIRED); BEND TO FORM RIGHT ANGLE
SAME FASTENERS AS
SLAB SIDE MOUNTING.
ONE BRACKET PER SIDE (MIN.); FOR EXTRA STABILITY, TWO
BRACKETS PER SIDE, 2" (50.8MM) FROM EACH CORNER.
Stabilizing Unit on Uneven Surfaces
To help stabilize an outdoor unit, some installations may re-
Page 10
COIL
BASE PAN
CORNER POST
MINIMUM ONE
PER SIDE
HEIGHT
AS
FOR EXTRA
STABILITY