Panasonic CS-A7CKP Service Manual page 9

Hide thumbs Also See for CS-A7CKP:
Table of Contents

Advertisement

Air Circulation
Motor
Rate
Fan Speed Low
Heat Exchanger
Description
Tube material
Fin material
Fin Type
Row / Stage
FPI
Size (W × H × L)
Refrigerant Control Device
Refrigeration Oil
Refrigerant (R-22)
Thermostat
Protection Device
Capillary Tube
Length
Flow Rate
Inner Diameter
Air Filter
Material
Style
Capacity Control
Compressor Capacitor
Fan Motor Capacitor
Note:
• Specifications are subject to change without notice for further improvement.
• (1) — CS-A9CKP/CU-A9CKP5 (Europe & CIS).
• (2) — CS-A9CKP-2/CU-A9CKP5-2 (Oceania).
• (3) — CS-A9CKP-6/CU-A9CKP5-6 (Turkey & Tunisia).
Unit
Type
Material
Type
Input
W
Output
W
rpm
Medium
rpm
High
rpm
SuperHigh
rpm
mm
3
(cm
)
g (oz)
mm
l/min
mm
µF, VAC
µF, VAC
CS-A7CKP CU-A7CKP5 / CS-A9CKP CU-A9CKP5 / CS-A12CKP CU-A12CKP5
CS-A9CK
Cross-flow Fan
AS + Glass Fiber 20%
Induction (4-poles)
44.8 - 53.5
15
Cooling; 780 - 780
Heating; 840 - 840
Cooling; 960 - 960
Heating; 960 - 960
(1)
Cooling; 1,140 - 1,140
(3)
Heating; 1,230 - 1,230
(2)
Cooling; 1,140 - 1,140
Heating; 1,230 - 1,230
Cooling; 1,230 - 1,230
Heating; 1,230 - 1,230
Evaporator
Copper
Aluminium (Pre Coat)
Slit Fin
(Plate fin configuration, forced draft)
2 × 15
19
610 × 315 × 25.4
Electronic Control
P.P.
Honeycomb
Capillary Tube
1.5 µF, 400VAC
9
CU-A9CK
Propeller Fan
PP Resin
Induction (6-poles)
56 - 64
29
805 - 820
805 - 830
Condenser
Copper
Aluminium (Blue Coat)
Corrugate Fin
1 × 20
16
841 × 508 × 22
Capillary Tube
SUNISO 4GSI (350)
860 (30.4)
Overload Protector
Cooling; 982, Heating; 325
Cooling; 5.4, Heating; 13.4
Cooling; 1.2, Heating; 1.4
30 µF, 400VAC
2.0 µF, 450VAC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-a9ckpCu-a9ckp5Cs-a12ckpCu-a12ckp5Cu-a7ckp5

Table of Contents