CS-A7CKP CU-A7CKP5 / CS-A9CKP CU-A9CKP5 / CS-A12CKP CU-A12CKP5
Indoor Unit
AUTO
OFF / ON
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
• Press continuously for 5s or < 10s to
operate Test Run/Pump down. "Beep"
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. "Beep, beep" sound will
be heard at the 10th second.
Operation Indication Lamps (LED)
•
(Green) ......... Lights up in operation,
POWER
•
(Orange) ......... Lights up in Quiet Mode
QUIET
•
(Orange) ......... Lights up in Timer
TIMER
•
POWERFUL
•
(Green) ............ Lights up in Ionizer
Operation Mode
• Heating, Cooling, Soft Dry and Automatic
Mode.
Powerful Operation
• Reaches the desired room temperature
quickly.
Quiet Operation
• To provide extra quiet operation.
Random Auto Restart Control
• Operation is restarted randomly after power
failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
blinks in Automatic
Operation Mode judging.
Operation.
Setting.
(Orange) ... Lights up in Powerful
Mode Operation.
Mode Operation.
Ionizer Control
• Ionizer control for generate negative ion in
discharge air.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
– Heating : Fan speed varies from Me →
– Cooling : Fan rotates at Hi, Me and SLo
– Soft Dry : Fan rotates at Lo- speed.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
Starting Current Control
• Fan motor is delayed for 1.6 seconds when
compressor starts simultaneously.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• Cooling Operation only.
30 Minutes Time Save Control
• Heating Operation only.
Hot-Start Control
• At Heating Operation the indoor fan will
operate at SLo speed when indoor heat
exchanger temperature reaches 30°C.
Anti Cold Draft Control
• The indoor fan operates at SSLo when the
indoor heat exchanger temperature is low.
(During Heating mode thermal off)
4
SSLo in accordance with
indoor heat exchanger.
speed. Deodorizing control is
available.
Deodorizing control is
available.