4.14 Procedure to check
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
start
Oscilloscope setting
1. Check
Power Source Block
2. Check
VCXO Block
3. Check
Ant. SW Module
Agilent 8960 : Test mode(WCDMA)
Ch. 9400 (Uplink)
Ch. 9800 (Downlink)
4. Check
WCDMA Block
Agilent 8960 : Test mode(GSM)
Ch. 190, P.L. 7 level setting
Ch. 190, -60dBm setting
5. Check
GSM Block
Redownload SW, Cal
- 105 -
4. TROUBLE SHOOTING
LGE Internal Use Only