Appliance Controls; Lighting The Appliance; On/Off Control; Adjusting Flame Height - Superior SLBV 35 Care And Operation Instructions Manual

Superior slbv 35; slbv 40 b-vent gas fireplaces
Hide thumbs Also See for SLBV 35:
Table of Contents

Advertisement

SUPERIOR

Appliance Controls

Operation of millivolt and electronic gas
control systems differs. Before lighting and
operating your appliance, determine whether
you have a millivolt or electronic appliance,
and then familiarize yourself with the location of
the Gas Control Valve and Gas Shut-Off Valve
on your specific appliance.
• For general control location, see Figure 1.
• For MILLIVOLT appliances, see Figure 3
• For ELECTRONIC appliances, see Figure 4

Lighting the Appliance

• Detailed MILLIVOLT appliance lighting
instructions are on Pages 22 and 23 and
also on the label attached to the gas
control valve.
• Detailed ELECTRONIC appliance lighting
instructions are on Pages 24 and 25
and also on the label attached to the
gas control valve. Also see "Lighting
an Electronic Appliance During a Power
Outage," below.
TO LIGHT YOUR APPLIANCE IN A POWER
OUTAGE:
• Confirm batteries installed in battery
pack.
• Turn unit mounted switch or wall switch
to the ON Position.
• Unit should spark at pilot and light.
NOTE: If no spark, replace batteries.
• Operate Normally.
Note:
Install fresh batteries in the battery holder
prior to the start of burn season, so the
fireplace can automatically switch to
battery power (4 "AA" batteries) in the
event of a power outage.
Main Gas Control Knob
IN
OUT
Manifold Pressure
Inlet
Port
Variable Flame
Pressure
Height Adjustment
Port
Gas Inlet
SIT Millivolt
Gas Control Valve
Figure 3
Terminals TPTH, TP and TH
B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • CARE AND OPERATION INSTRUCTIONS
®

ON/OFF Control

Available ON/OFF control options for both
MILLIVOLT and ELECTRONIC models include a
unit-mounted ON/OFF switch (shown in Figure
1 ), a wall switch, or a remote control system.
See the "Accessory Components" section in
this manual for details.
Note: To prevent excessive resistance in
burner circuit (which can cause burner op-
eration problems), wire only one burner
control switch to the valve.

Adjusting Flame Height

After lighting the appliance, rotate the Flame
Height Adjustment Knob to adjust the flame in
a variable range from "LOW" to "HI" (manual
adjustment only; no remote options).
• For MILLIVOLT appliances, see Figure 3.
• For ELECTRONIC appliances, see Figure 4.
CONTROLS FOR OPTIONAL
OUTSIDE COMBUSTION AIR KIT
An optional outside combustion air system
may be used with these appliances to provide
supplemental combustion air from outside the
home during appliance operation. If used, the
outside combustion air kit must be installed
before the fireplace is framed and enclosed in
the finished wall.
The Outside Air Control Lever for this type of
system is standard on all models (see Figure
5 ); however, do NOT operate the Outside Air
Control Lever if the complete system is NOT
installed.
When a complete outside supplemental com-
bustion air system is installed, the installer will
remove the securing screw from the control
lever on the LEFT side of the fireplace opening
(see Figure 5).
If the securing screw has NOT been removed,
and you have reason to believe your fireplace
has a complete outside supplemental combus-
Gas Inlet
tion air system, contact your dealer or distribu-
tor to have your appliance inspected.
Inlet (IN) Test Port
Manifold (OUT)
Test Port
Orange Wire
(from DFC
Wire Harness)
Terminals TPTH, TP and TH
Main
Gas Inlet
3/8 in. NPT
Gas
Outlet
Figure 4: SIT Electronic Gas Valve
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
The hand-operated outside air control lever is
located on the lower LEFT side of the fireplace
opening. See Figure 5.
To open the outside air shutter, open the bot-
tom control access panel, reach into the control
compartment, and pull the outside air control
lever all the way out. The outside air shutter
should be fully open when the fireplace is in use
and completely closed when the fireplace is not
being used. Closing it when not in use will greatly
reduce the amount of outside cold air entering
the dwelling through the fireplace.
Hi/Lo
Green Wire
Flame
(from DFC Wire
Control
Harness)
Knob
Gas
Outlet
Figure 5
Do not operate the shutoff lever
unless a complete outside com-
Yellow Ground Wire
bustion air system has been
(from DFC Wire
Harness)
installed with your appliance.
IMPORTANT: Do NOT assume your fire-
place has a complete supplemental com-
bustion air system, and do NOT operate
the Outside Air Control Lever unless you
have verified with your dealer or distribu-
tor that a complete system is in place.
Securing
Screw
Installed
Outside Air Control
Lever pushed UP
(Air Shutter CLOSED)
IMPORTANT: Do NOT move Air Control
Lever if securing screw is installed
(or if not sure it was removed).
Securing
Screw
Removed
Outside Air Control
Lever pulled DOWN
(Air Shutter OPEN)
Left Side of
Lower Control Compartment
WARNING
9