Diagnostic Error Code
011-196-XXX Serial port test halt, error threshold exceeded
011-197-XXX Serial port test warning
011-198-XXX Serial port test aborted
011-199-XXX Serial port test failed, cause unknown
011-2XX-XXX Serial port signal failure
014-000-XXX Parallel port Interface Test Passed
014-001-XXX Parallel port Presence
014-002-XXX 014-003-XXX Parallel port Timeout/Parity
error
014-013-XXX 014-014-XXX Parallel port Control
Signal/Loopback test failure
014-015-XXX Parallel port External Loopback failure
014-027-XXX Parallel port Configuration/Setup error
014-03X-XXX 014-04X-XXX Parallel port failure
014-195-XXX Parallel port Test aborted by user
014-196-XXX Parallel port test halt, error threshold
exceeded
50
ThinkStation Hardware Maintenance Manual
FRU/Action
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 37.
2. Re-run test
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 37.
2. Flash the system and re-test. See "Updating
(flashing) the BIOS" on page 169.
3. Go to "Undetermined problems" on page 65.
1. Go to "Undetermined problems" on page 65.
2. Flash the system and re-test. See "Updating
(flashing) the BIOS" on page 169.
3. Replace component under function test.
1. External serial device
2. System board
No action
1. Remove external parallel device, if present.
2. Run the Setup Utility program, enable port
3. System board
System board
System board
1. Wrap plug
2. System board
1. Run the Setup Utility program, enable port
2. Flash the system. See "Updating (flashing) the
BIOS" on page 169.
3. System board
System board
Information only Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.