Louver Control; Louver Position; Air Direction Adjustment; Swing - Toshiba RAS-10SKVP2-E Service Manual

Split type indoor unit high wall, heat pump type outdoor unit heat pump type
Table of Contents

Advertisement

Item

8. Louver control

This function controls the air direction of the indoor unit.
• The position is automatically controlled according to the operation
1) Louver
position
mode (COOL/HEAT).
• The set louver position is stored in memory by the microcomputer,
and the louver returns to the stored position when the next operation
is performed. (Cooling/Heating memory position)
The angle of the louver is indicated as the louver closes fully is 0°.
1) Louver position in cooling operation
2) Louver position in heating operation

2) Air direction adjustment

Horizontal
blowing
• Swing operation is performed in width 35° with the stop position as

3) Swing

the center.
• If the stop position exceeds either upper or lower limit position,
swing operation is performed in width 35° from the limit which the
stop position exceeded.
Operation flow and applicable data, etc.
Initial setting of "Cooling storage position"
Louver : Directs downward (35.3°)
Heating operation/
AUTO (HEAT)
Initial setting of "Heating storage position"
Louver : Directs downward (80.5˚)
Air direction
Inclined
Blowing
blowing
downward
Inclined
Horizontal
blowing
blowing
32
FILE NO. SVM-11015
Description
• The louver position can
be arbitrarily set up by
pressing [FIX] button.
• Swing
When pressing
[SWING] button during
operation, the louver
starts swinging.