Operation And Function Of The Domestic Hot Water Heat Pump; Operation And Display - Dimplex BWP 30 HS Installation And Operating Instructions Manual

Hot water heat pump for indoor installation
Table of Contents

Advertisement

Available languages

Available languages

BWP 30HS - BWP 30HSD
7
Operation and function
of the domestic hot
water heat pump

7.1 Operation and display

7.1.1 Description key functions and
pilot lamps
Menu key:
Switches to the main menu, where detailed set-
tings for the heat pump can be made.
Rapid heating key:
Press 1x flange heater on for a set
time, time adjustable with the arrow keys starting
from 0.5 h to max. 4 h
Press 2x flange heater permanently on
Press 3x electric heating element in automatic
Pilot lamp:
mode, i.e. switched on automatically when
needed
Rapid heating pilot lamp (red)
Permanently if the flange heater was switched
on manually for a defined time
Flashing if the flange heater was switched to
continuous operation manually
On/Off key:
Switch heat pump on/off; the frost protection
function is active when the heat pump has been
switched off. (DHW set value: 20 °C)
Pilot lamp:
Pilot lamp permanently on (green)
Heat pump is ready
ESC key:
Return to the previous menu level
OK key:
Beginning and completion of a parameter
change / selection of a desired menu item;
special function in the start screen: Current
actual temperatures are displayed alternately
Up arrow key:
Increase a value / select menu and parameter;
special function in the start screen: Increase
domestic hot water setpoint
Down arrow key:
Decrease a value / select menu and parameter;
special function in the start screen: Decrease
domestic hot water setpoint
EN-8
7.1.2 Description of displays
7.1.3 Display
Query current operating data:
The current operating data can be queried at any time using the
"OK" key in the start screen. The following data are available
Display of current operating statuses (footer)
451903.66.11 · FD 9401
Current setpoint for domestic hot water
The value can be changed here by pressing the keys.
Domestic hot water temperature in the cylinder (top)
Collector temperature (if a Pt 1000 sensor is connected)
Domestic hot water temperature in the cylinder (bottom)
Air intake temperature
Request domestic hot water preparation
The domestic hot water setpoint is not reached.
Compressor running
Domestic hot water request is being processed
Compressor running
Photovoltaic mode active, see Cap. 7.3.6 on pag. 12
Solar gain present (circulating pump switched on), see Cap. 7.3.5
on pag. 12
2nd heat generator active (circulating pump switched on), see Cap.
7.3.4 on pag. 11
Flange heater active, see Cap. 7.3.2 on pag. 11
Time program running (block / thermal disinfection) active, see Cap.
7.3.1 on pag. 11
Pure ventilation mode without domestic hot water preparation, see
Cap. 7.3.3 on pag. 11
Ventilation mode active
www.dimplex.de

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bwp 30 hsd

Table of Contents