Lenovo THINKCENTRE 8084 Hardware Maintenance Manual page 74

Lenovo computer accessories user manual
Table of Contents

Advertisement

68
Hardware Maintenance Manual
Diagnostic Error Code
011-195-XXX
Serial port Test aborted by user
011-196-XXX
Serial port test halt, error threshold exceeded
011-197-XXX
Serial port test warning
011-198-XXX
Serial port test aborted
011-199-XXX
Serial port test failed, cause unknown
011-2XX-XXX
Serial port signal failure
014-000-XXX
Parallel port Interface Test Passed
014-001-XXX
Parallel port Presence
014-002-XXX
014-003-XXX
Parallel port Timeout/Parity error
014-013-XXX
014-014-XXX
Parallel port Control Signal/Loopback test
failure
014-015-XXX
Parallel port External Loopback failure
014-027-XXX
Parallel port Configuration/Setup error
FRU/Action
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 55
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 55
2. Flash the system and re-test. See "Flash
update procedures" on page 214
3. Go to "Undetermined problems" on page
90
1. Go to "Undetermined problems" on page
90
2. Flash the system and re-test. See "Flash
update procedures" on page 214
3. Replace component under function test
1. External serial device
2. System board
No action
1. Remove external parallel device, if
present
2. Run setup, enable port
3. System board
System board
System board
1. Wrap plug
2. System board
1. Run Setup, enable port
2. Flash the system. See "Flash update
procedures" on page 214
3. System board