Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
Installation and service must be per-
formed by a qualified installer, ser-
vice agency or the gas supplier.
£
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
If the information in this manual is not
followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Extinguish any open flames.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
G24M
SERIES
50HZ

GAS FURNACE

Litho USA

Advertisement

loading

Summary of Contents for Lennox G24M SERIES

  • Page 1: Gas Furnace

    Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. G24M SERIES 50HZ GAS FURNACE Litho USA...
  • Page 2 8 - TRANSFORMER 9 - BLOWER DOOR INTERLOCK SWITCH Do not use this furnace if any part has been under- water. Immediately call a qualified service techni- cian to inspect the furnace and to replace any part of the control system and any gas control which has been under water.
  • Page 3: Important Directions

    Your furnace is a gas appliance. It is critical that the gas supplied to the unit be completely burned to avoid the pro- duction of carbon monoxide gas. Complete combustion...
  • Page 4 OFF. Do not force. 5 - Replace the access panel. Filters G24M series units are equipped with external filters which should be inspected monthly and replaced when neces- sary to assure proper furnace operation. See table 1 for filter sizes. Replacement filters used with G24M-40/60/75 units must have a minimum velocity rating of 400 FPM.
  • Page 5: Burner Flame

    UPFLOW FURNACE BOTTOM RETURN AIR FIGURE 4 UPFLOW FURNACE SIDE RETURN AIR FIGURE 5 DOWNFLOW FURNACE FILTERS IN PLENUM RACK FIGURE 6 Blower Check and clean blower wheel for any debris. Blower mo- tor is prelubricated for extended bearing life. No further lu- brication is needed.
  • Page 6: Planned Service

    Fresh air grilles and louvers (on the unit and in the room where the furnace is installed) - Must be open and unob- structed to provide combustion air. Burners- Must be inspected for rust, dirt, or signs of wa- ter.

This manual is also suitable for:

G24m-45G24m-60G24m-75G24m-100G24m-120G24m-140