Lennox Hearth Products Montage 32FS Installation And Operation Manual page 9

Free-standing pellet stove elite series
Hide thumbs Also See for Montage 32FS:
Table of Contents

Advertisement

Prior to lighting your appliance:
q Review the safety precautions section.
q Review the pellet FUEL section.
q Review and follow the Operating Instructions.
q Plug power cord connector into corresponding connector on the back
of appliance (see Figures 7 and 8 showing connector locations).
After you have begun operation of your appliance:
q Review the routine cleaning / maintenance information.
q Enjoy the warmth from your new Lennox Hearth Products pellet
stove!
Damper Location, Installation And Adjustment
Damper Air Control
Located behind the right side panel on model Montage 32FS.
Adjustment Procedure
Using a 1/4" nut driver or socket, loosen the damper setscrew (see
Figure 6). Adjust in 1/4" increments until optimum combustion air flow
is achieved. Retighten the damper setscrew.
For less air push in and for more air pull out.
Standard Setting
3/4" (19mm)
Figure 6 - Damper Adjustment
IMPORTANT NOTE: Install the thermostat per the manufacturers instruc-
tions, provided with the thermostat. Failure to follow manufacturers
instructions could result in a malfunction. Pay special attention to the
thermostat location requirements. If the location requirements are not
adhered to the appliance, erratic operation or failure may occur.
Do not mount the thermostat where it may be affected by:
• Radiant heat from the stove, fireplaces, sun or other heat sources.
• Drafts or dead spots behind doors or in corners.
• Hot or cold air from ducts.
Thermostat Installation:
Note: Always Disconnect Power Before Performing The Thermostat
Installation.
Loosen Setscrew
to Adjust Damper
Damper
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
A 24 volt wall thermostat and 20 feet of 18-gage thermostat wire is included
in the accessory package. It is recommended that the thermostat and
thermostat wire be installed by an Lennox Hearth Products dealer.
Thermostat wires and purple wires from wire har-
ness will connect to these  terminals
Jumper
Remove jumper if Thermostat IS to be used
Leave jumper on, if thermostat is NOT used
Figure 7 - Terminal Block
Installation Steps:
1. Unplug stove power cord from the wall outlet.
2. Locate the thermostat terminal block (see Figures 7 and 8).
3. Loosen the two terminal screws on the terminal block and remove the
jumper.
4. Connect the two wires from your thermostat to the terminals (one
per terminal). Ensure that the purple wires from the harness remain
connected to the terminal block and tighten the terminal screws. Make
sure the wires are firmly connected to the thermostat.
5. Plug in the stove and you are ready to operate with your thermo-
stat!
Note: See Wiring Diagram on Page 27.
IMPORTANT
If the wall thermostat provided is not used, the
jumper is required for the stove to operate.
Figure 8 - Terminal Block Location
Route thermostat wires
through this grommet
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents