C O N T EN T S
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . 1
OUTLINE AND DIMENSIONS . . . . . . . . . . . 2
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . 5
ERROR DISPLAY . . . . . . . . . . . . . . . . . . . . 10
DISASSEMBLY ILLUSTRATION . . . . . . . . . 12
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . 20
Outdoor unit
AOY30LMBWL
AOY36LMBWL
. . . . 6
. . . 7

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ABY30LBAG

  • Page 1: Table Of Contents

    CEILING type (50Hz) Models Indoor unit Outdoor unit ABY30LBAG AOY30LMBWL ABY36LBAG AOY36LMBWL C O N T EN T S SPECIFICATIONS ..... . 1 OUTLINE AND DIMENSIONS .
  • Page 2: Specifications

    SP EC I FIC ATI ONS TYPE COOLING & HEATING INDOOR UNIT ABY30LBAG ABY36LBAG OUTDOOR UNIT AOY30LMBWL AOY36LMBWL COOLING CAPACITY (kW) 8.50 10.0 HEATING CAPACITY (kW) 10.0 10.8 ELECTRICAL DATA POWER SOURCE FREQUENCY 1 50Hz COOLING 13.1 18.0 RUNNING CURRENT HEATING 12.7...
  • Page 3: Outline And Dimensions

    O U TLI NE AN D D IMENSI O N S (Unit : mm) INDOOR UNIT Models : ABY30LBAG ABY36LBAG 1,660 1,600 2005.11.08 www.enindel.com...
  • Page 4 OUTDOOR UNIT (Unit : mm) Models : AOY30LMBWL AOY30LMBWL Air Flow 2005.11.08 www.enindel.com...
  • Page 5: Refrigerant System Diagram

    REFR IGER A NT SYST E M DI A G R A M Models : ABY30LBAG / AOY30LMBWL ABY36LBAG / AOY36LMBWL INDOOR UNIT OUTDOOR UNIT Pressure Refrigerant Pipe Check Valve 15.88mm (5/8") High Pressure Switch Charging Valve 4-way Valve Evaporator...
  • Page 6: Circuit Diagram

    C IRCU IT D IA GR A M INDOOR UNIT Models : ABY30LBAG ABY36LBAG DISPLAY BOARD WHITE GRAY CONTROL BOARD WHITE GRAY BLACK BLACK BLACK FILTER BLACK BOARD OUTDOOR UNIT Models : AOY30LMBWL AOY36LMBWL 2005.11.08 www.enindel.com...
  • Page 7: Indoor Pcb Circuit Diagram

    INDOO R PC B C IRC U IT D I AGRA M CONTROLLER PCB ASSEMBLY ( MAIN PCB ) ABY30LBAG : K01AL-050FHSE-C1 Models : ABY30LBAG ABY36LBAG : K01AL-050GHSE-C1 ABY36LBAG R15 - R17 10K <1/10W> x 3 B2B-XASK-1-A ROOM TEMPERATURE THERMISTOR...
  • Page 8: Outdoor Pcb Circuit Diagram

    O UT D OOR PCB C IR C UIT DIAG RAM Models : AOY30LMBWL AOY36LMBWL CHOKE COIL L=0.3MH INVERTER ASSEMBLY EMI FILTER RFC-9 UL1015 1 TURN AOY30LMBWL : EZ-00500HUE AWG12 UL1015 UL1015 WHITE AOY36LMBWL : EZ-00501HUE AWG14 AWG14 UL1015 UL1015 POWER SOURCE WHITE BROWN...
  • Page 9 Models : AOY30LMBWL AOY36LMBWL C201 - C203 500/450V x 3 MAIN CURRENT CONTROLLER PCB ASSEMBLY ( MAIN PCB ) YELLOW R200 ZPR0RCH400 R201 C116 AOY30LMBWL : K04AW-0509HUE-C1 220K 0.1 <HCP> R370, R371, R373, R374 0.03 <2W> x 4 <2W> R375, R376, R378, R379 0.03 <2W> x 4 AOY36LMBWL : K04AW-050AHUE-C1 BLACK C115...
  • Page 10 Models : AOY30LMBWL AOY36LMBWL POWER SUPPLY PCB ASSEMBLY K04BA-0401HUE-P0 TM100 N300300K1D7C RCH4730-021PF07 RCH4730-021PF07 BLACK TM101 VA101 C104 470V 0.033 C107 C111 C101 <TNR> <YE> POWER SOURCE VA102 C105 230V <LE> <LE> <LE> 0.033 470V 50Hz <TNR> <YE> TM102 WHITE C106 SA100 <LE>...
  • Page 11: Error Display

    ER R OR C ONT ENT S (Ind o o r u n it ) Operation can be checked by lighting and flashing of the display section OPERATION, TIMER, and VERTICAL SWING lamps. Perform judgment in accordance with the following. VERTICAL SWING lamp (Orange) TIMER lamp (Green) OPERATION lamp (Red)
  • Page 12 ERRO R C ON TE NT S ( o utdoor un i t ) SPECIAL INSTALLATION CAUTION SETTING Always turn on the power 12 hours prior to the start of the operation in order to ensure compressor protection PUMP DOWN (Refrigerant collecting operation) 1.
  • Page 13: Disassembly Illustration

    D I SASSE M B L Y IL L U ST R AT I O N INDOOR UNIT Models : ABY30LBAG ABY36LBAG 2005.11.09 www.enindel.com...
  • Page 14 Models : ABY30LBAG ABY36LBAG 876-1 2005.11.09 www.enindel.com...
  • Page 15 Models : ABY30LBAG ABY36LBAG 876-2 2005.11.09 www.enindel.com...
  • Page 16 Models : ABY30LBAG ABY36LBAG 253-5 253-3 253-4 253-6 253-7 253-2 253-1 185-1 982-1 381-4 815-1 982-2 2005.11.09 www.enindel.com...
  • Page 17 Models : AOY30LMBWL AOY36LMBWL 2005.11.09 www.enindel.com...
  • Page 18 Models : AOY30LMBWL AOY36LMBWL 2005.11.09 www.enindel.com...
  • Page 19 Models : AOY30LMBWL AOY36LMBWL 2005.11.09 www.enindel.com...
  • Page 20 Models : AOY30LMBWL AOY36LMBWL 33 34 2005.11.09 www.enindel.com...
  • Page 21: Parts List

    PAR T S L I ST INDOOR UNIT Part No. Part No. Ref. Ord. Ref. Ord. Description Description Q'ty Q'ty ABY30LBAG ABY36LBAG ABY30LBAG ABY36LBAG Air Filter 9359739005 9359739005 345-1 Filter Guide-R 9359692003 9359692003 Base Assy 9359680000 9359680000 345-2 Filter Guide-L...
  • Page 22 OUTDOOR UNIT Part No. Ref. Ord. Description Q'ty AOY30LMBWL AOY36LMBWL Top Panel Sub Assy 9374417025 9374417025 Front Panel 9374094066 9374094066 Fan Guard 9374330010 9374330010 Grip Side 9374173013 9374173013 Service Panel Sub Assy 9374415038 9374415038 Right Panel Sub Assy 9374416066 9374416066 Emblem Rear 9351355005 9351355005...
  • Page 23: Standard Accessories

    STANDARD ACCESSORIES The following installation parts are furnished. Use them as required. INDOOR UNIT ACCESSORIES Name and Shape Q'ty Application Name and Shape Q'ty Application Remote Use for air conditioner Coupler heat insulator (large) For indoor side pipe joint control unit operation (Gas pipe) Coupler heat insulator (small)