LOG PLACEMENT GUIDE FOR LENNOX DIRECT VENT EDV3530, EDV4035
AND EDV4540 SERIES VENTED GAS FIREPLACE HEATERS
GENERAL INFORMATION
This log placement guide has been prepared to present detailed log
placement illustrations and provide instruction to assist in the place-
ment of logs at the initial (new appliance) setup and after the annual
cleaning and inspection cycles. The information provided here is to
be used in conjunction with the Homeowner's Care and Operation In-
structions provided together with this document in the appliance lit-
erature packet. Please read the Homeowner's Care and Operation In-
structions completely before completing the procedures detailed in
this placement guide.
INITIAL INSTALLATION CONSIDERATIONS
If the logs are being installed for the first time, the following para-
graphs apply:
DO NOT attempt to install the logs until the appliance installation has
been completed, the gas line connected and tested for leaks and the
initial burner operation has been checked out.
Step 1. Remove the appliance front door.
Step 2. Remove the boxed log set from the interior of the firebox.
Remove the logs from their packaging. Handle logs carefully to pre-
vent breakage.
CERAMIC EMBER PANELS, LOGS AND GLOWING EMBER
PLACEMENT
Step 1. Install the Ceramic Ember Panels as shown in Figure 3 . Panels
should be placed in the order shown.
A. Place the left and right panel against the corners as shown.
B. Align the two front legs of the grate assembly on the dimples and
align the two rear legs between the cut out as shown.
C. Place the front panel into its proper position as shown. Adjust the
panels to minimize the gaps.
Note: This appliance is provided with enough Glowing Embers for sev-
eral applications, do not feel compelled to use all that is in a new bag.
For best glowing effect, replace the ember material annually. Replace-
ment Glowing Embers are available (Catalog Number 88L53).
Step 2. Position the individual logs as shown in Figures 4 and 5 . Logs
should be placed in the order shown. All logs that have notches to fit
over the grate tines should be positioned with these notches directly
against the grate.
750,158M
REV. N/C 05/2003
Figure 1
Figure 2
Proper log placement is critical to encourage outstanding flame
appearance and prevent sooting. When positioned properly as
shown, logs will be positioned between flame peaks and will not
impinge any flames.
Step 3. Separate the Glowing Ember (Rockwool) into pieces about
the size of a quarter Figure 1 . Keep the pieces fluffed up, not matted.
Distribute these pieces over the front surface of the burner, as shown
in Figure 2 . Do not use more than is necessary. When properly posi-
tioned, the Glowing Embers will cover approximately 65% of the front
burner and with no appreciable gaps or openings. Ensure that the
main burner ports remain uncovered by the ember material.
Refer to page 3 for EDV3530 Series appliances and to page 4 for
EDV4035 & EDV4540 Series appliances.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
LOG PLACEMENT GUIDE
EDV3530, EDV4035 AND
EDV4540 SERIES
Glowing Embers
1

Advertisement

loading

Summary of Contents for Lennox EDV3530 series

  • Page 1 Ensure that the main burner ports remain uncovered by the ember material. Refer to page 3 for EDV3530 Series appliances and to page 4 for EDV4035 & EDV4540 Series appliances. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 2 Catalog Number for the entire Ceramic Ember Panel set: 55M4601 (For EDV3530), 55M4701 (For EDV4035) Left Side Panel Left Side Panel Grate Assembly Must Rest On Dimples In Firebox Sub-Floor Left Side Panel CERAMIC EMBER PANEL PLACEMENT And 55M4801 (For EDV4540).
  • Page 3 Align The Holes In One End Of Logs 2 & 3 Over The Locating Pins And Align The Grooves On The Other End Over The Grate And Push It Toward The Rear EDV3530 LOG PLACEMENT Number Catalog Number for the entire log set: 55M0201...
  • Page 4 Number Description Log, Rear Log, Diagonal/Left Log, Diagonal/Right Log, Front/Left Log, Top/Right Log, Front/Center Catalog Number for the entire log set: 55M0301 Align Groove At The Bottom Locating Pins Of Log (1) Over The Grate And Push It Towards The Rear. Align The Holes In One End Of Logs 2 &...

This manual is also suitable for:

Edv4540 seriesEdv4035 series