Drain Motor And Valve; Brake Adjustment - Daewoo DWF-750 Service Manual

Auto washer
Hide thumbs Also See for DWF-750:
Table of Contents

Advertisement

Drain Motor and Valve

¡ Lay the front of the washer on the floor.
¡ Loosen the adjustment screw and two bolts
mounting the drain motor.
¡ Take out the wire of drain motor from the bracket.
Drain motor
Wire Bracket

Brake Adjustment

¡ Loosen the adjustment screw fastening the brack-
et and place the adjustment screw to the brake
lever as shown in figure.
¡ Tighten the adjustment screw completely.
3.0mm
Adjustment bolt
(Non pump model)
¡ Loosen the adjustment bolt and turn the adjust-
ment bolt until the end of the bolt touches to the
brake lever.
¡ Tighten the lock nut and apply a small amount of
paint-lock.
Adjustment bolt
Clutch lever
Gear mechanism ass'y
Adjustment
screw
Adjustment
screw
Brake lever
Clutch lever
Brake lever
¡ Separate the drain motor from the bracket.
¡ Turn the valve lid by using screw driver as shown
in figure and remove the valve lid from the valve
frame.
Valve frame
Screw dirver
Valve lid Pin Bellows
¡ Tighten the link brake screw completely.
Link brake
Adjustment bolt
(Pump model)
NOTES:
1. The brake adjustment has been made at the
factory, so that it is not re-adjust.
However, in case of insufficient brake operation,
problem the upper procedure.
2. Overtightening of the adjustment bolt will cause
poor brake performance.
3. Undertightening of the adjustment bolt will
cause continuous braking and thereby.
cause the problems of the motor during the
spingcycle.
Bracket
Adjustment
screw
Valve lid
Brake lever
Clutch lever
DIRECTIONS
19