Notes For The Diagnostic Program - Casio SE-S400 Service Manual

Electronic cash register
Hide thumbs Also See for SE-S400:
Table of Contents

Advertisement

5-3. Notes For The Diagnostic Program

• All test results from a two-printer-type model are printed from the Receipt Printer.
• For the number of test to perform, you may select "once" or "infinite loop".
If "0" is entered as the number of times to perform the test, the test will be performed only once.
If any value between "1" and "9" is entered, the test is repeated infinitely. To forcibly terminate the
infinite loop, press
• When the Mode Switch is [OFF], all displays are turned off and no diagnostic commands are
accepted.
• To forcibly terminate a test, press
If a test is terminated, the device prints out the following:
ESC
• If a command of 10 digits or more is entered, the values entered initially are canceled.
1
2
1
2
If the above command is entered, the values indicated with double-lined boxes will be displayed in
the main display.
The first two digits, "1" and "2", will be canceled and, therefore, will not be displayed.
• When a command starts with "0", "0" will not be printed.
• When printed characters are hidden behind the printer cover, press "FEED" key to advance the
printer paper.
key or turn the Mode Switch to [OFF].
C
key or turn the Mode Switch to [OFF].
C
3
4
5
6
7
8
– 19 –
SE-S400/PCR-T500/PCR-T520/SE-C450/
SE-S3000/PCR-T2300/PCR-T2400/SE-C3500
9
0
s .