G. MOTOR-ASSY
G-1. Undo two screws.
G-2. Remove the MOTOR-ASSY.

MOTOR-ASSY

NOTES ON ASSEMBLY
Be sure to attach CUSHION/120X6 when replacing the PS-UNIT.
Attach the cushion in the middle as shown in the photo and fold the edges.
SE-S400/PCR-T500/PCR-T520/SE-C450/
SE-S3000/PCR-T2300/PCR-T2400/SE-C3500
H. PS-UNIT
H-1. Remove the PS-UNIT.
Screws (S1)

PS-UNIT

CUSHION/120X6