6.5

Troubleshooting flow chart

1
Power is not supplied.
Is the AC cable connected correctly?
Yes
No
Connect the AC cable correctly.
Is fuse F1 on the transformer assy/or F1 on the control/power supply board blown?
No
Yes
Replace fuse (with same type and rating).
Remedied?
No
Does DC + 8V out?
No
Yes
Remove Printhead. (Turn power off, then on.)
Remedied?
No
Replace carriage cable or ribbon feed mechanism.
Remedied?
No
Replace Control/Power supply board.
Remove CN3 on Driver board.
Measure for any short circuits between + 5V, + 40V, + 8V, 0V (EL or EP).
Any short circuit?
No
Yes
42089201TH Rev.4
Yes
End
Yes
End
Yes
End