16.4 Industrial Interface
Board,
cont'd.
Intermec EasyCoder 601 XP – Service Manual Ed. 2
Industrial Interface Configuration
The Industrial Interface provides:
• 8 digital IN ports with opto-couplers (Opto In)
• 8 digital OUT ports with opto-couplers (Opto Out)
• 4 OUT ports with relays (Relay Out)
The Industrial Interface has no straps or circuits to be fitted or
removed. All signals are available on a female DB44 connector and
the various ports are controlled by the Intermec Fingerprint instruc-
tions PORTIN and PORTOUT ON/OFF (see Intermec Fingerprint
7.12 Reference Manual).
Digital Opto In
The status of the digital IN ports 101–108 can be read by means of
PORTIN functions. If a current is led through the opto-coupler of
the port, PORTIN returns the value -1 (true), else the value 0 (false).
Signal
Description
Vin [High]
Input Voltage High
Vin [Low]
Input Voltage Low
Connector Configuration
Pin
Signal Name Description
10
IN1A
Anode Opto In Channel 1 +
40
IN1K
Cathode Opto In Channel 1 -
26
IN2A
Anode Opto In Channel 2 +
11
IN2K
Cathode Opto In Channel 2 -
41
IN3A
Anode Opto In Channel 3 +
27
IN3K
Cathode Opto In Channel 3 -
12
IN4A
Anode Opto In Channel 4 +
42
IN4K
Cathode Opto In Channel 4 -
28
IN5A
Anode Opto In Channel 5 +
13
IN5K
Cathode Opto In Channel 5 -
43
IN6A
Anode Opto In Channel 6 +
29
IN6K
Cathode Opto In Channel 6 -
14
IN7A
Anode Opto In Channel 7 +
44
IN7K
Cathode Opto In Channel 7 -
30
IN8A
Anode Opto In Channel 8 +
15
IN8K
Cathode Opto In Channel 8 -
VCC
R17
IC8D
8
9
74HC14
Simplified schematics of a digital IN port.
Chapter 16
Min,
10V
-1V
TIL193B
R25
IC16D
7
10
9
C27
8
GND
Interfaces
Typical
Max.
24V
40V
0V
1V
Fingerprint Ref. No.
101
102
103
104
105
106
107
108
P4
R33
10
IN1A
40
IN1K
121