2 Display
Service ROM Check
Service ROM Sum Check 1 : PASS!!(or ERROR!!)
Service ROM Sum Check 2 : PASS!!(or ERROR!!)
IPL PROGRAM Version
∗∗
←Display the version
APL PROGRAM Version
27801R∗∗∗∗ UP-3301
27801R∗∗∗∗ UP-3301
27801R∗∗∗∗ UP-3301
27801R∗∗∗∗ UP-3301
BLOCK Version
20=∗∗ 21=∗∗ 22=∗∗ 23=∗∗ 24=∗∗ 25=∗∗ 26=∗∗ 27=∗∗
28=∗∗ 29=∗∗ 2A=∗∗ 2B=∗∗ 2C=∗∗ 2D=∗∗ 2E=∗∗ 2F=∗∗
3 Terminating procedure
After displaying the test result, press the Touch panel to terminate
the check.
3) SSP Check
1 Check content
By starting this diagnostic program, the SSP setting for testing is
automatically performed and the SSP check is executed and the
result is displayed.
The SSP check sets data for checking in the vacant space of the
SSP entry register, and deletes the data that is checked after com-
pletion of the test. Therefore, existing data is not changed by this
check.
2 Display
SSP Check
SSP (NMI) Check
3 Terminating procedure
After displaying the test result, press the Touch panel to terminate
the check.
3-4. Timer Diagnostics
The operation of the clock crystal of the CKDC and the keyboard are
tested.
When the CANCEL key is pressed, the display returns to the diagnos-
tics menu.
1) Timer Check
1 Check
The operation of the CKDC9 clock crystal is checked.
The indication "YY/MM/DD & MM:HH:SS" is continuously updated.
Check the time updated and indicated.
Timer Diagnostics
DATE&TIMER=YY/MM/DD &HH:MM:SS
:
:
: PASS!! (ERROR!!)
UP-3301US DIAGNOSTICS SPECIFICATIONS
3-5. Touch Panel Diagnostics
1) Touch Panel Check
1 Check
The input test of the touch panel is as follows: a rectangle of dotted
lines is displayed at the corner of the LCD screen in the order of
upper right, upper left, lower left, and lower right. Check whether a
catch sound is heard and the rectangle turns black when each posi-
tion is touched.
Touch Panel Diagnostics
Touch Cursor!!
2 End
The test is over when the four corners have been touched. To exit,
please press the touch panel.
3-6. RS232 I/F Diagnostics
The main PWB and the optional PWB (RS232 interface of ER-A7RS2)
are checked. Attach the 9-pin D-Sub loop back connector (UKOG-
6717RCZZ). The wiring diagram is shown below (Fig. 6-1).
The following menu is displayed. Press the desired key for the opera-
tion you want to execute for the individual diagnostics programs.
Pressing the CANCEL key returns the screen to the Diag MAIN menu.
IMPORTANT : : : : When setting channels for the RS232, do not set two or
more ports to one channel. In the UP-3301, a max. two
units of ER-A7RS2 can be installed. On each PWB, do
not set two or more ports to the same channel. If two or
more ports should be set to the same channel, the hard-
ware can be damaged.
RS232 I/F Diagnostics
CHANNEL Check
CH1 Check
CH3 Check
CH4 Check
CH5 Check
CH6 Check
CH8 Check
– 26 –